期刊文献+

头颈部多层螺旋CT扫描辐射剂量系统性优化的研究现状与展望 被引量:14

原文传递
导出
摘要 已成为头颈部疾病的常规检查方法,但其辐射剂量明显高于普通x线检查。美国检查数量只占全部放射线检查的11%-13%,但辐射剂量却占60%以上。临床上检查数量正在快速增长,美国每年检查人次已达7500万,其中30%-40%的部位为头颈部,患者接受的平均有效辐射剂量为1~5mv。目前辐射剂量带来的潜在危害备受关注。M的成像特点、射线剂量分布特征、
出处 《中华放射学杂志》 CAS CSCD 北大核心 2013年第11期1051-1053,共3页 Chinese Journal of Radiology
  • 相关文献

参考文献32

  • 1Mettier FA,Wiest PW,Locken JA,et al.CT scanning:patterns of use and dose.J Radiol Prot,2000,20:353-359.
  • 2Van Unnik J,Broerse JJ,Geleijns J,et al.Survey of CT techniques and absorbed dose in various Dutch hospitals.Br J Radiol,1997,70:367-371.
  • 3刘士远,于红.CT低剂量扫描的研究和应用现状[J].中华放射学杂志,2013,47(4):295-300. 被引量:79
  • 4van der Molen AJ,Geleijns J.Overranging in multisection CT:quantification and relative contribution to dose--comparison of four 16-section CT scanners.Radiology,2007,242:208-216.
  • 5Niu YT,Olszewski ME,Zhang YX,et al.Experimental study and optimization of scan parameters that influence radiation dlose in temporal bone high-resolution multidetector row CT.AJNR Am J Neuroradio1,2011,32:1783-1788.
  • 6Valentin J.International Commission on radiation protection.Managing patient dose in multi-detector computed tomography (MSCT).ICRP Publication 102.Ann ICRP,2007,37:1-79.
  • 7Kalender WA,Wolf H,Suess C.Dose reduction in CT by anatomically adaptod tube current modulation.Ⅱ.Phantom measurements.Med Phys,1999,26:2248-2253.
  • 8McCollough CH,Bruesewitz MR,Kofler JM Jr.CT dose reduction and dose management tools:overview of available options.Radiographics,2006,26:503-512.
  • 9Bauknecht HC,Jach C,Bohner G,et al.Impact of image noise levels,scout scan dose and lens shield on image quality and radiation exposure in z-axis dose-modulated neck MSCT on 16-and 64-slice Toshiba Aquilion scanners.Eur J Radiol,2010,73:439-443.
  • 10Mulkens TH,Bellinck P,Baeyaert M,et al.Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations:clinical evaluation.Radiology,2005,237:213-223.

二级参考文献48

  • 1邓大平,王燕南,孙秀兰,侯金鹏,宗西源.X射线CT检查阳性检出率调查及其合理应用[J].中华放射医学与防护杂志,1995,15(4):272-273. 被引量:11
  • 2吴爱琴,郑文龙,许崇永,程建敏,陈宇,陈廷港.低剂量CT扫描在新生儿缺氧缺血性脑病中的应用和防护价值[J].中华放射医学与防护杂志,2006,26(5):528-530. 被引量:11
  • 3Brenner DJ,Hall EJ. Computed tomography: an increasing source of radiation exposure. N Engl J Med ,2007.357:2277-2284.
  • 4Valentin J, International Commission on Radiation Protection. Managing patient dose in muhidetector computed tomography (MDCT) : ICRP Publication 102. Ann ICRP, 2007, 37:1-79.
  • 5Hal El. Lessons we have learned from our children : cancer risks from diagnostic radiology. Pediatr Radial ,2002,32:700-706.
  • 6Hart D, Hillier MC, Wall BF, et al. National reference doses for common radiographic, fluoroscopic and dental X-ray examinations in the UK. Br J Radio1,2009,82 : 1-12.
  • 7Imhof H, Schibany N, Ba-Salamah A, et al. Spiral CT and radiation dose. Eur J Radiol,2003 ,47 :29-37.
  • 8ICRP. Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53 ). Ann ICRP, 1998,28: 1-126.
  • 9Naidich DP, Marshall CH, Gribbin C, et al. Low-dose CT of the lungs : preliminary observations. Radiology, 1990,175 : 729-731.
  • 10Christner JA, Zavaletta VA, Eusemann CD, et al. Dose reduction in helical CT: dynamically adjustable Z-axis X-ray beam collimation. A JR Am J Roentgenol,2010,194 : W49-W55.