摘要 目的:探讨SPACE序列三维快速自旋回波成像技术在正常臂丛神经节后段磁共振成像中的应用价值。方法:对35名无臂丛神经损伤病史的健康志愿者行臂丛神经DWIBS序列、SPACE序列扫描。分析比较DWIBS序列、SPACE序列可清晰显示臂丛神经的数目,以及两组序列图像平均信噪比(SNR)和对比噪声比(CNR)。结果:35名共70侧臂丛神经节后段在冠状DWIBS序列、SPACE序列上均能清晰显示,SPACE序列中部分臂丛内侧束、后束和外侧束也可显示。SPACE序列的图像信噪比和对比噪声比高于DWIBS序列,且差异具有统计学意义。结论:SPACE序列可以清楚地显示臂丛神经节后段,与DWIBS序列相比较对正常臂丛神经显像具有更高的清晰度。 Objective: To investigate the value of enhanced 3D SPACE sequence in displaying brachial plexus. Methods:35 healthy volunteers with no history of brachial plexus injury of brachial plexus MRI examinations by DWIBS scan, and SPACE scanned. Analysis and comparison of DWIBS sequences, sequences of SPACE provides a clear display of the brachial plexus, and two sets of image sequence average signal-to-noise ratio (SNR) and the contrast to noise ratio (CNR). Results:A total of 35 cases 70 lateral brachial plexus after coronary DWIBS is clearly displayed on the sequence;the partial medial cord of brachial plexus, beams and lateral beams can also be displayed in the SPACE sequence. SPACE sequence of image signal-to-noise ratio and contrast noise ratio than the DWIBS sequence, and the difference is statistically significant. Conclusion:SPACE sequence can clearly show the brachial plexus, and DWIBS sequences compared to the normal image has a higher resolution of the brachial plexus.
出处 《中国医学装备》 2013年第12期113-116,共4页 China Medical Equipment
关键词 臂丛神经 弥散加权成像 SPACE序列 磁共振 Brachial plexus Diffusion-weighted Imaging, SPACE sequence Magnetic resonance imaging
  • 相关文献

参考文献10

  • 1Filler AG,Kilot M,Howe FA,et al.Application of magnetic resonance neurography in the evaluation of patient with peripheral nerve pathology[J]. J Neurosurg, 1996,85(2) : 299-309.
  • 2Takahara T,Hendrikse J,Yamashita T,et al.Diffusionweighted MR neurography of the brachial plexus:feasibility study[J].Radiology, 2008,249(2) :653-660.
  • 3高立,梁碧玲,张赟,沈君,钟镜联,叶瑞心.背景信号抑制弥散加权成像在臂丛神经影像诊断的应用[J].中山大学学报(医学科学版),2007,28(3):322-326. 被引量:24
  • 4Skorpil M,Engstrom M,Nordell A.Diffusion- direction dependent-imaging:a novel MRI approach for peripheral nerve imaging[J].Magn Reson Imaging, 2007,25(3) :406-411.
  • 5Mugler JP,Kiefer B,Brookeman JR.Three diamensional T2-weighted imaging of the using very long spin-echo train in:Proceedings of the international society for magnetic resonancein Medicine[C]. Berkeley, Calif: ISMRM, 2000: 1630.
  • 6Mugler JP,Meyer H,Kiefer B.Practical implementation of optimized tissue specific prescribed signal evolutions for improved turbo-spin echo imaging. In:proceedings of the International Society for Magnetic Resonance in Medicine[C]. Berkeley, Calif: ISMRM, 2003: 203.
  • 7许道洲,夏好成,罗树彬,吕海莲,冯国平,许蕾,肖文丰,王忠.磁共振SPACE序列在诊断极外侧椎间盘突出中的临床应用[J].中国医学计算机成像杂志,2011,17(4):356-360. 被引量:12
  • 8Filler AG,Maravilla KR,Tsuruda JS.MR neurography and muscle MR imaging for image diagnosis of disorders affecting the peripheral nerves and musculature[J].Neurol Clin, 2004,22(3): 643-682.
  • 9赵斌,蔡世峰,高佩虹,彭洪娟.MR扩散加权成像鉴别乳腺良恶性病变的研究[J].中华放射学杂志,2005,39(5):497-500. 被引量:146
  • 10李新春,陈健宇,刘庆余,沈君,梁碧玲.正常臂丛节后神经MR神经成像术[J].中国医学影像技术,2004,20(1):105-107. 被引量:36

二级参考文献33

  • 1刘溢,谢敬霞,韩鸿宾,杨渝平,刘淳.磁共振扩散加权成像在乳腺肿瘤的初步应用[J].中国医学影像技术,2003,19(5):548-551. 被引量:38
  • 2欧常学,黄卫明,何平.螺旋CT扫描与多平面重建诊断极外侧型腰椎间盘突出症[J].现代诊断与治疗,2005,16(3):145-146. 被引量:4
  • 3李明全,袁志,陈拱诒.极外侧型腰椎间盘突出症[J].中华骨科杂志,1995,15(4):239-240. 被引量:24
  • 4[1]Posniak HV, Olson MC, Dudiak CM, et al. MR imaging of brachial plexus[J]. AJR,1993,161(2):373-379.
  • 5[3]Hayes CE, Tsuruda JS, Mathis CM, et al. Brachial plexus: MR imaging with a dedicated phased array of surface coils[J]. Radiology, 1997, 203(1):286-289.
  • 6[4]Kuntz C, Blake L, Brize G, et al.Magnetic resonance neurography of pheripheral nerve lesions in the lower extremity[J]. Neurosurgy, 1996, 39()4:750-759.
  • 7[5]Filler AG, Kliot M, Franklyn AH, et al. Application of magnetic resonance neurography in the evaluation of patients with peripheral nerve pathology[J]. J Neurosurg,1996,85(2):299-309.
  • 8[6]Mccarthy M. MRI simplifies diagnosis of peripheral nerve lesions[J]. Lancet, 1996,348(9028): 674.
  • 9[7]Howe FA, Filler AG, Bell BA, et al. Magnetic resonance neurography[J]. Magn Res Med, 1992,28(2):328-338.
  • 10Sugahara T, Korogi Y, Kochi M, et al. Usefulness of diffusion-weighted MRI with echo-planar technique in the evaluation of cellularity in gliomas. J Magn Reson Imaging, 1999, 9:53-60.

共引文献207

同被引文献50

  • 1陈建宇,刘庆余,沈君,梁碧玲,高明勇,叶瑞心,钟镜联.臂丛神经损伤的 MRI 诊断[J].中华放射学杂志,2007,41(6):563-568. 被引量:18
  • 2Filler AG, Kliot M, Howe FA, et al. Application of magnetic resonance neurography in the evaluation of patients with peripheral nerve pathology. J Neurosurg, 1996, 85(2): 299-309.
  • 3Viallon M, Vargas MI, Jlassi H, et al. High-resolution and functional magnetic resonance imaging of the brachial plexus using an isotropic 3D T2 STIR (Short Term Inversion Recovery) SPACE sequence and diffusion tensor imaging. Eur Radiol, 2008, 18(5): 1018-1023.
  • 4Vargas MI, Viallon M, Nguyen D, et al. New approaches in imaging of the brachial plexus. Eur J Radiol, 2010, 74(2): 403- 410.
  • 5Reeder SB, Yu H, Johnson JW, et al. T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation. J Magn Reson Imaging, 2006, 24(4): 825-832.
  • 6Takahara T, Imai Y, Yamashita T, et al. Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display. Radiat Med, 2004, 22(4): 275- 282.
  • 7Yoneyama M, Takahara T, Kwee TC, et al. Rapid high resolution MR neurography with a diffusion-weighted pre- pulse. Magn Reson Med Sei, 2013, 12(2): 111-119.
  • 8Takahara T, Hendrikse J, Yamashita T, et al. Diffusion- weighted MR neurography of the brachial plexus: feasibility study. Radiology, 2008, 249(2): 653-660.
  • 9Tagliafico A, Calabrese M, Puntoni M, et al. Brachial plexus MR imaging: accuracy and reproducibility of DTI-derived measurements and fibre tractography at 3.0-T. Eur Radiol, 2011, 21(8): 1764-1771.
  • 10Hodel J,Silvera J,Bekaert O,et al. Intracranial cerebrospinal fl- uid spaces imaging using a pulse-triggered three-dimensional turbo spin echo MR sequence with variable flip-angle distribution[J]. Eur Radiol,2011,21:402-410.

引证文献5

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部