期刊文献+

高频燃烧红外吸收光谱法测定碳酸钴中的硫 被引量:8

Determination of Sulfur in Cobalt Carbonate by Infrared Absorption Spectrometry Method after High Frequency Combustion
在线阅读 下载PDF
导出
摘要 采用高频燃烧红外吸收光谱法测定碳酸钴中的硫,在测定过程中先将样品进行灼烧处理,并选用纯铁和钨助熔剂熔样,解决了水分干扰和样品熔解不完全的问题。方法可以准确测定碳酸钴中质量分数为0.001%~0.01%的硫,加标回收率为98.4%~101.4%,相对标准偏差RSD为2.8%~6.3%。 Sulfur in cobalt carbonate samples was determined by infrared absorption spectrometry method with high frequency combustion.In the process of determination,the samples were firstly burned and then melted in pure iron and tungsten fluxing medium.This method solved the problems of moisture interference and incomplete sample melting.The method can accurately determine the sulfur with mass fraction in cobalt carbonate as 0.001%~0.01%.The spiked recovery rates are between 98.4%~101.4% and relative standard deviations are between 2.8%~6.3%.
作者 骆月英
出处 《中国无机分析化学》 CAS 2013年第4期49-51,共3页 Chinese Journal of Inorganic Analytical Chemistry
关键词 高频燃烧 碳酸钴 助熔剂 high frequency combustion cobalt carbonate fluxing medium sulfur
  • 相关文献

参考文献3

二级参考文献8

  • 1杨fan.2000年全国冶金气体分析学术报告会议论文集[M].洛阳,2000.38.
  • 2肖红新,庄艾春.高频燃烧红外吸收法测定钼酸铵中的硫[A].2001年中国用户学会学术交流会论文集(下集)[C].2001.
  • 3LECO-CS-344碳硫红外分析仪说明书[M].何顺绶译.冶金部分析情报网,1985.
  • 4天津化工研究院,等.无机盐工业手册(上册)[M].北京:化学工业出版社,1988.
  • 5GB/T13293.13-91.高纯阴极铜化学分析方法[S].北京:中国标准出版社,1992.
  • 6北京矿冶研究总院.矿石及有色金属分析手册[M].北京:冶金工业出版社,2001.
  • 7杨王番,2000年全国冶金气体分析学术报告会论文集,2000年,38页
  • 8GB1 4 67 78氧化钴中蒸馏 示波极谱法测定硫量