摘要 背景:陶瓷对陶瓷全髋关节置换适用于活动量较大、生活质量要求较高的年轻患者。目的:分析陶瓷对陶瓷全髋关节置换治疗青壮年患者股骨颈骨折近期治疗效果。方法:使用陶瓷对陶瓷全髋关节置换治疗的年龄在50岁以下的中青年股骨颈骨折患者51例,评估患者治疗后髋关节功能及并发症。结果与结论:所有患者均获随访,随访时间6个月至3年8个月。末次随访时,Harris评分为(92.0±3.4)分,优良率94.1%。置换后无关节脱位病例发生,3例轻度跛行,均未作特殊处理。至随访结束影像学检查结果显示,未见假体松动、下沉及碎裂发生,假体周围无透亮线形成。陶瓷对陶瓷人工髋关节置换治疗活动量相对较大的青壮年患者股骨颈骨折能有效减少因磨损碎屑造成的骨溶解,减少假体的松动及下沉,延长关节的使用寿命,改善患者的生活质量。 BACKGROUND:Ceramic-on-ceramic total hip arthroplasty can be applied to young patients requiring frequent activity and high quality of life. OBJECTIVE:To explore the short-term efficiency of ceramic-on-ceramic total hip arthroplasty in young and middle-aged patients of femoral neck fractures. METHODS:Fifty-one young and middle-aged patients under 50 years old with ceramic-on-ceramic total hip arthroplasty were selected to analyze the function of hip joints and the complication after operation. RESULTS AND CONCLUSION:Al the patients were fol owed up for 6 months to 44 months. At the last fol ow-up, the average Harris score was 92.0±3.4 points with an excellent and good rate of 94.1%. No dislocation was observed and three cases exhibited mild limping. Imaging examination showed that, no prosthesis loosing, broken, sinking or radiolucent line around prosthesis was observed. Ceramic-on-ceramic total hip arthroplasty in young patients with femoral neck fractures can effectively decrease the osteolysis, prosthesis loosing and sinking caused by the debris of wearing, prolong the working life of the prosthesis, and improve the patient’s quality of life.
出处 《中国组织工程研究》 CAS CSCD 2013年第52期8955-8960,共6页 Chinese Journal of Tissue Engineering Research
关键词 骨关节植入物 人工假体 关节成形术 假体 陶瓷 骨折 股骨颈 中青年 并发症 arthroplasty, hip hip prosthetics ceramics femoral neck fractures
  • 相关文献

参考文献35

二级参考文献325

共引文献197

同被引文献66

  • 1陈怀,张嵘,周斌,陈志勇.微机械陀螺仪温度特性及补偿算法研究[J].传感器技术,2004,23(10):24-26. 被引量:38
  • 2Lewinnek GE, Lewis JL, Tarr R, et al. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60(2):217-220.
  • 3Prikhodko IP, Zotov SA, Trusov AA, et al. Foucault pendulum on a chip: Angle measuring silicon MEMS gyroscope. Micro Electro Mechanical Systems (MEMS), 2011 IEEE 24th International Conference. 2011.
  • 4Peters FM, Greeff R, Goldstein N, et al. Improving acetabular cup orientation in total hip arthroplasty by using smartphone technology. J Arthroplasty. 2012;27(7): 1324-1330.
  • 5Hohmann E, Bryant A, Tetsworth K. A comparison between imageless navigated and manual freehand technique acetabular cup placement in total hip arthroplasty. J Arthroplasty. 2011 ;26(7): 1078-1082.
  • 6Bosker BH, Verheyen CC, Horstmann WG, et al. Poor accuracy of freehand cup positioning during total hip arthroplasty. Arch Orthop Trauma Surg. 2007; 127(5):375-379.
  • 7Gandhi R, Marchie A, Farrokhyar F, et al. Computer navigation in total hip replacement: a meta-analysis. Int Orthop. 2009;33(3):593-597.
  • 8Basso T, Klaksvik J" Syversen U, et al. Biomechanical femoral neck fracture experiments--a narrative review. Injury. 2012; 43(10):1633-1639.
  • 9Souder CO, Brennan ML, Brennan KL, et al. The rate of contralateral proximal femoral fracture following closed reduction and percutaneous pinning compared with arthroplasty for the treatment of femoral neck fractures. J Bone Joint Surg Am. 2012;94(5):418-425.
  • 10steen R0, Lofthus CM, Nordsletten L, et al. Randomized trial of hemiarthroplasty versus internal fixation for femoral neck fractures: no differences at 6 years. Clin Orthop Relat Res. 2014;472(1):360-367.

引证文献4

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部