550kV SF_6/N_2充气母线绝缘性能研究 被引量:19

Insulation Performance of 550kV SF_6/N_2 Busbar
在线阅读 下载PDF
导出
摘要 由于SF6气体的温室效应,减少SF6气体的使用具有深远的社会意义,用SF6/N2混合气体取代纯SF6气体作为高压电器设备的绝缘介质是减少使用SF6气体的有效措施。介绍了SF6/N2混合气体的优点。从气体放电理论出发,对不同比例SF6/N2混合气体的绝缘性能进行了分析,结果表明:SF6体积分数仅为20%的SF6/N2混合气体击穿强度为相同气体压力纯SF6的70%左右;若SF6体积分数为20%的SF6/N2混合气体的击穿强度要达到纯SF6气体的击穿强度,其总压力应为纯SF6气体的1.4倍。新东北电气集团高压开关有限公司研制的采用20%SF6和80%N2混合气体绝缘,总压为0.6 MPa的550 kV SF6/N2混合气体母线在机械工业高压电器产品质量检测中心(沈阳)顺利通过了绝缘型式试验,且其雷电冲击耐受水平高达1 842.5 kV。因此,用SF6/N2混合气体作为550 kV母线的绝缘介质是切实可行的。 Due to greenhouse effect of SF6, it is necessary to substitute SF6/N2 gas mixture for SF6 gas as insulation medium in electric power equipment. In this paper, advantages of SF6/N2 mixtures are discussed. The insulation performances of the SF6/N2 gas mixtures with different SF6 contents are analyzed according to gas discharge theory. The results show that: the critical field strength of the SF6/N2 gas mixture with 20% of SF6 in volume reaches 70% that of pure SF6 under same pressure, and the SF6/Nz gas mixture with 20% SF6 can achieve the same critical field strength with that of pure SF6 if the pressure of the mixture is 1.4 times of that of pure SF6. The 0.6 MPa 20% SFs/ 80%N2 gas mixture insulated 550 kV busbar developed by New Northeast Electric Group High Voltage Switchgear Co., Ltd. has passed the insulation tests in High Voltage Apparatus Quality Test & Research Center of Machinery Industry(Shenyang), and its lightning impulse withstand level reaches to 1 842.5 kV.
出处 《高压电器》 CAS CSCD 北大核心 2014年第1期77-80,共4页 High Voltage Apparatus
关键词 气体绝缘开关设备 SF6 N2混合气体 母线 绝缘性能 gas insulated switchgear SF6/N2 gas mixture busbar insulation performance
  • 相关文献

参考文献2

二级参考文献21

  • 1G.Schoeffner,T.Neumann.气体绝缘管道输电线和气体绝缘组合电器在电厂中的应用[J].电力建设,2004,25(6):4-7. 被引量:21
  • 2邱毓昌,冯允平,张鸣超.SF_6/N_2混合气体绝缘介质的研究[J].西安交通大学学报,1993,27(1):1-6. 被引量:18
  • 3Qiu Yuchang, Kufffel E.Comparisonof SF6/N2 and SF6/ CO2 Gas Mixtures as Alternative to SF6 Gas[J]. IEEE Trans onDEI,1999,6(6):892~895.
  • 4Christophorou L G, Olthoff J K, Van Brunt R J. Sulfur Hexafluoride and the ElectricPower Industry [J].IEEE Electrical Insulation Magazine,1997, 13(5): 20~24.
  • 5Qiu X. Q., Chalmers I D, Coventry P. A Study of Alternative Insulating Gases toSF6[J]. J.Phys.D:Appl. Phys.,1999,32: 2918~2922.
  • 6Singha S,Thomas M.J. Very Fast Transient Over- voltages in GIS with CompressedSF6-N2 Gas Mixtures.IEEE Trans. on DEI,2001,8(4):658~664.
  • 7Ueno H, Sakamoto N, Nakayama H. Anomalous Creeping Flashover Characteristics inN2/SF6 Mixed Gas under Single Pulse Voltage[J].IEEE Trans on DEI, 2001,8(2):195~202.
  • 8Biarra T B,Béroual A,Buret F et al.N2/SF6 Mixtures for High Voltage GasInsulated Line[C]. 1997,10th ISH.
  • 9Dissenter A, Finkel M, Grund A, Kynast E. Dielectric Properties of N2/SF6 Mixturesfor Use in GIS or GIL[C]. 1999,11th ISH.
  • 10Marsden H I, Dale S J, Hopkins M D, Eck III C R. High Voltage Performance of a GasInsulated Cable with N2 and N2/SF6 Mixture[C].1997, 10th ISH.

共引文献79

同被引文献198

引证文献19

二级引证文献258

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部