期刊文献+

半淹没式旋转孔板污水取水机设计与应用 被引量:3

Design and application of semi-submerged rotary orifice plate sewage-source heat pump intake machine
在线阅读 下载PDF
导出
摘要 分析了半淹没式旋转孔板污水取水机的工作原理,建立了半淹没式旋转孔板污水取水的动态数学模型和针对位置的稳态数学模型。在稳态数学模型的基础上,给出了取水机孔板过流量、孔板过滤负荷、孔板平均堵塞系数的计算方法,并给出了实例计算。通过计算结果分析了污水浓度对孔板过流量、孔板过滤负荷、孔板平均堵塞系数的影响。介绍了其性能测试方法,并对实际工程应用的取水机进行了现场测试。 Analyses the operating principle of semi-submerged rotary orifice plate sewage intake machine, and develops the dynamic mathematical model and steady-state mathematical model with position. Based on the steady-state mathematical model, provides the calculation method of the orifice plate filter capacity, the orifice plate filter load and the average blockage coefficient of orifice plate, and illustrates a calculation example. Based on the calculation result, analyses the effect of contaminant concentration on the orifice plate filter capacity, the filter load and the average blockage coefficient of orifice plate. Presents the performance test method and performs the field test of intake machine applied in an actual project.
出处 《暖通空调》 北大核心 2014年第1期134-139,共6页 Heating Ventilating & Air Conditioning
基金 新疆建设兵团科技局科技支撑计划项目(编号:2011AB025) 江苏省科技支撑计划项目(编号:BE2010645)
关键词 污水源热泵 设计方法 过流量 过滤负荷 堵塞系数 sewage-source heat pump, design method, filter capacity, filter load, blockage coefficient /
  • 相关文献

参考文献4

二级参考文献77

共引文献48

同被引文献27

  • 1张亚立,孙德兴,张吉礼.污水水源热泵供热技术经济性分析[J].建筑热能通风空调,2006,25(4):64-66. 被引量:3
  • 2钱剑峰,吴学慧,孙德兴,吴荣华.管壳式污水换热器结垢厚度对流动换热的影响[J].流体机械,2007,35(1):74-78. 被引量:17
  • 3谭洪卫,李潇潇,朱金明,等.黄浦江水温变化规律与上海地区江水源热泵节能潜力研究[C]//上海市制冷学会2007年学术年会论文集.上海:2007.
  • 4ZHAO X L, FU L, ZHANG S G, et al. Study of the perform- ance of an urban original source heat pump system [ J ]. Energy Conversion and Management, 2010, 51 (4) : 765 -770.
  • 5NORIO A, ATSUSHI I. Evaluation of energy use in district heat- ing and cooling plant using sewage and one using air as heat source [ J ]. Journal of the Japan Institute of Energy, 2000, 79 (5) : 446 -454.
  • 6QIAN J F, LIU Y Y, XU Y, et al. Study on characteristics of ultrasonic descaling and heat transfer enhancement in sewage source heat pump system [J]. Applied Mechanics and Materi- als, 2014, 525 : 603 - 606.
  • 7QIAN J F. Study on Operation and parameters of urban sewage source heat pump system with freezing latent heat collection [ J]. Advanced Materials Research, 2012, 403 : 3235 - 3238.
  • 8PEDERSEN S E, STENE J. 18 MW heat pump system in Nor- way utilizes untreated sewage as heat source [ J ]. IEA Heat Pump Centre Newsletter, 2006, 24(4): 37- 38.
  • 9FUNAMIZU N, IIDA M, SAKAKURA Y, et al. Reuse of heat energy in wastewater: implementation examples in Japan [ J ]. Water Science & Technology, 2001,43 ( 10 ) : 277 - 285.
  • 10BAEK N C, SHIN U C, YOON J H. A study on the design and analysis of a heat pump heating system using wastewater as a heat source [J]. Solar Energy, 2005, 78(3) : 427 -440.