摘要
采用溶胶-凝胶法在NiTi形状记忆合金表面制备了TiO2-SiO2复合薄膜,在提高医用NiTi合金的抗腐蚀性方面,收到了显著的效果.运用电化学方法对不同组成的TiO2-SiO2薄膜在模拟体液中的腐蚀行为进行了研究,结果表明,随薄膜中 Ti/Si比的增加,TiO2-SiO2薄膜的抗腐蚀性增强.划痕试验表明 TiO2-SiO2(Ti/Si=4:1)膜与NiTi合金基体具有较高的界面结合强度.用原子力显微镜(AFM)对TiO2-SiO2薄膜的表面形貌及表面粗糙度进行观察和分析,解释并讨论了TiO2-SiO2薄膜的配方组成与其抗腐蚀性的关系,SiO2含量较少时,薄膜结构致密,膜层均匀平滑,且膜基结合力好,作为医用NiTi合金的表面保护层,可以使其耐腐蚀性有显著提高.
Sol-gel-derived TiO2-SiO2 films on NiTi Shape Memory Alloy were prepared. The corrosion behavior of TiO2-SiO2 films with different compositions was studied in Tyrode's solution. The results indicate that the corrosion resistance will be enhanced with the increasing of Ti/Si molar ratio in the film. A scratching test and AFM observation show that the TiO2-SiO2 film (Ti/Si=4:1) is bonded strongly to the substrate. AFM analyses of surface morphology and roughness indicate that the TiO2-SiO2 film (Ti/Si=4:1) is compact, uniform and smooth. The relationship between the composition and corrosion resistance of TiO2-SiO2 films was discussed. The TiO2-SiO2 films with a small amount of SiO2 have good corrosion resistance and can be used as protective layers on NiTi alloy for biomedical applications.
出处
《无机材料学报》
SCIE
EI
CAS
CSCD
北大核心
2001年第1期75-80,共6页
Journal of Inorganic Materials
基金
国家科技部科技攻关项目!(96-907-04-05)
国家高技术863新材料领域专家委员会资助项目!(715-002-024