摘要 实验研究了内导流筒式三相好氧生物流化床处理低浓度废水时高分子载体表面生物膜的形成条件以及操作条件对生物膜厚度的影响。实验结果表明 ,在水力停留时间 2 .5~ 3h ,有机容积负荷 6 .0 1~ 7.0 8kgCOD/(m3·d)条件下 ,能培养出稳定的生物膜 ,13d膜厚达 10 0 μm以上 ;当有机容积负荷率为 15kgCOD/(m3·d)时 ,生物膜厚度为140 μm ,此时生物膜活性最好 ,COD去除率最高 ;如果供氧充分 ,有机负荷在 5~ 15kgCOD/(m3·d)时 ,载体表面有稳定的生物膜 ,尽管生物膜厚度不同 ,但COD去除率均在 85 The experiments were conducted in a three phase fluidized bed bioreactor with internal loop to investigate the effects of operation codition on the formation of biofilm on a porous polymer carrier,for treating the wastewater of low condition. The results show that,under the condition of the HRT of 2.5~3 h and the organic volume load rate of 6.01~7.08 kgCOD/(m 3·d),the biofilm begions to form steadily on the carrier surface and reaches more than 100 μm in thickness after 13 days. When the organic volume load rate is 15 kgCOD/(m 3·d) ,the biofilm of 140 μm thick has the best activation and the highest remaval rate of COD.With enough supply of oxygen,the biofilm can form steadily on the carrier surface for the organic volume load rate of 5~15 kgCOD/(m 3·d) and although different in thickness, gives COD removal rate of more than 85%.
出处 《四川大学学报(工程科学版)》 EI CAS CSCD 2001年第1期42-45,共4页 Journal of Sichuan University (Engineering Science Edition)
基金 国家自然科学基金资助项目! (2 96 76 0 2 7)
关键词 二相流化床 生物流化床 生物膜 废水处理 膜厚 biofilm fluidized bed biofilm wastewater treatment
  • 相关文献

参考文献4

二级参考文献12

共引文献22

同被引文献27

  • 1周平,王世和.生物膜厚度对流化床反应器性能影响分析[J].环境科学,1994,15(2):1-5. 被引量:12
  • 2肖鸿,杨平,郭勇,方章平.生物膜反应器中生物膜脱落的机理及数学模型[J].化工环保,2005,25(1):23-28. 被引量:12
  • 3姜家顺,施汉昌.蜂窝断面内循环三相生物流化床处理生活污水的中试研究[J].给水排水,2005,31(4):115-115. 被引量:4
  • 4OCHIENG A, ODOYO O, MUTSAGO M. Biological treatment of mixed industrial wastewaters in a fluidized bed reactor [J]. Journal of Hazardous Materials, 2003,B96:79- 90.
  • 5TIJHUIS L. Formation and growth of heterotrophic aerobic biofilms on small suspended partical in airlift reactors[J]. Biotechnology and Bioengineering, 1994,44: 595 -608.
  • 6LAMOTTA E J. Kinetics of growth and substrate uptake in a biological film system [J]. Applied and Environmental Microbiology, 1976,31: 286 - 293.
  • 7NicoMla C, van Loosdrecht M C M, Heijnen J J. Wastewater treatment with particulate biofilm reactors. J Biotechnol, 2000,80( 1 ):1-33.
  • 8Shich W K, Lepore J A, Zandi I. Biological fluidized bed treatment of ethylene and propylene glycols. Wat. Sci. Tech., 1998,38 (4-5) : 145- 153.
  • 9杨平,郭勇.适用于有机废水的生物处理设备.中国发明专利受理号:02128135.1
  • 10Campos J L, Sanchez M, Mosquera-Corral M, et al. Coupled BAS and anoxic USB system to remove urea and formaldehyde from wastewater. Water Research, 2003,37 : 3445-3451.