期刊文献+

梯度折射率光纤探针聚焦性能的曲线拟合评价 被引量:2

Curve fitting for evaluating the focusing performance of the gradient-index fiber probe
在线阅读 下载PDF
导出
摘要 研究一种高精度曲线拟合方法,用于评价超小梯度折射率光纤探针的聚焦性能。首先,概述梯度折射率光纤探针模型;其次,根据高斯光束通过梯度折射率光纤探针进行聚焦的特点,提出利用多项式拟合的方法评价聚焦的束腰位置和光斑尺寸;最后,进行评价方法的验证分析。结果显示,由曲线拟合方法得到的工作距离为0.93 mm,束腰直径为28.2μm,与实验测得的工作距离1 mm和束腰直径28μm基本一致。表明所研究的基于多项式拟合的曲线拟合方法适于梯度折射率光纤探针聚焦性能的评价。 A high-precision curve fitting method was investigated so evaluate the focusing performance of an ultra-small gradient-index (GRIN) fiber probe. Firstly, an overview of the GRIN fiber probe model is given. Secondly,according to the characteristics of Gaussian beam focusing through the GRIN fiber probe ,the polynomial fitting method is proposed to evalu- ate the waist position and spot size of the focused beam. Finally,the evaluation method is analyzed for validation. The re- sults show that, with the curve fitting method, the obtained working distance and waist diameter are 0.93 mm and 28.2 μm, respeetively. Under the same conditions, the experimentally measured working distance and waist diameter are 1 mm and 28 13μn,accordingly. The fitting results are in good agreement with the experiment data. Therefore,the proposed polynomial curve fitting method is applicable to evaluate the focusing performance of GRIN fiber probe.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2014年第2期453-459,共7页 Chinese Journal of Scientific Instrument
基金 国家自然科学基金(41104065) 上海市教委"晨光计划"(12CG047) 上海市教委科研创新基金(13YZ022) 精密测试技术及仪器国家重点实验室开放基金资助项目
关键词 光学相干层析技术 梯度折射率光纤探针 小型光学探头 曲线拟合 optical coherence tomography (OCT) gradient-index (GRIN) fiber probe small optical probe curve fit- ting
  • 相关文献

参考文献25

  • 1HUANG D, SWANSON E A, LIN C P, et al. Optical co- herence tomography [ J ]. Science, 1991,54 ( 5035 ) : 1178-1181.
  • 2GUO S, YU L, SEPEHR A, et al. Gradient-index lens rod based probe for office-based optical coherence tomography of the human larynx [ J ]. Biomed. Opt., 2009, 14( 1 ) :014017.
  • 3XIE T, GUO S, CHEN Z. GRIN lens rod based probe for endoscopic spectral domain optical coherence tomography with fast dynamic focus tracking [ J ]. Optics Express, 2006,14(8) :3238-3246.
  • 4XIE T, LIU G, KREUTER K, et al. In vivo three-dimen- sional imaging of normal tissue and tumors in the rabbit pleural cavity using endoscopic swept source optical co- herence tomography with thoracoseopic guidance [ J ]. Bi- omed. Opt. ,2009,14(6) :064045.
  • 5MEEMON P,LEE K, MURALI S, et al. Optical design of a dynamic focus catheter for high-resolution endoscopic optical coherence tomography [ J ]. Applied Optics, 2008, 47(13) :2452-2457.
  • 6MINE J. NA J, RYU S Y. et al. Sinzle-bodv lensed-fiberscanning probe actuated by magnetic force for optical ima- ging[ J]. Optics Letters,2009,34(12) :1897-1899.
  • 7SWANSON E, PETERSEN C L, MC NAMARA E, et al. Ultrasmall optical probes, imaging optics, and methods for using same : USA ,6445939 [ P]. 2002.
  • 8REED W A, YAN M F, SCHNITZE M J R. Gradient-in- dex fiber-optic microprobes for minimally invasive in vivo low-coherence interferometly [J]. Opt. Lett. , 2002,27 : 1794-1796.
  • 9JAFRI M S, FARHANG S, Tang R S, et at. Optical coher- ence tomography in the diagnosis and treatment of neurologi- cal disorders [ J ]. J. Biomed. Opt. ,2005,10(5 ) :051603.
  • 10MAO Y X, CHANG S D. Graded-index fiber lens proposed for ultrasmall probes used in biomedical imaging [ J ]. Appl. Opt. ,2007,46 (23) :5887-5894.

二级参考文献134

共引文献118

同被引文献17

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部