期刊文献+

Rapid Detection of Acetylbritannilactone from Inula britannica in Plasma of Rats by Online Sweeping-Micellar Electrokinetic Chromatography

Rapid Detection of Acetylbritannilactone from Inula britannica in Plasma of Rats by Online Sweeping-Micellar Electrokinetic Chromatography
原文传递
导出
摘要 Objective To establish a rapid method for detecting acetylbritannilactone (ABL) by online sweeping-micellar electrokinetic chromatography (MEKC) and to elevate the sensitivity of the detection. Methods The combination of online sweeping technique with MEKC was used to determine the content of ABL in the extract of Inula britannica in plasma of rats. Results ABL was completely separated within 15 min in running buffer and sample buffer. The optimal conditions were as follows: on uncoated fused quartz silica capillary, with separation voltage of 23 kV, capillary temperature of 25 oC, and detection wavelength of 195 nm. The regression equations revealed good linear relationships between the peak area and concentration of ABL (r = 0.998), with the detection limits of 0.005-0.15 mg/mL. The relative standard deviations of migration time and peak areas for intra- and inter-batch were 〈 2.45% and 〈 2.26%, respectively. The recovery rate of this method was 96.3~97.2%. Conclusion This method provides some advantages in separation speed, testing sensitivity, and operating convenience, with low sample and reagent consumption. The online sweeping-MEKC is an effective method for pharmacokinetic study and analysis on tracing biological samples. Objective To establish a rapid method for detecting acetylbritannilactone (ABL) by online sweeping-micellar electrokinetic chromatography (MEKC) and to elevate the sensitivity of the detection. Methods The combination of online sweeping technique with MEKC was used to determine the content of ABL in the extract of Inula britannica in plasma of rats. Results ABL was completely separated within 15 min in running buffer and sample buffer. The optimal conditions were as follows: on uncoated fused quartz silica capillary, with separation voltage of 23 kV, capillary temperature of 25 oC, and detection wavelength of 195 nm. The regression equations revealed good linear relationships between the peak area and concentration of ABL (r = 0.998), with the detection limits of 0.005-0.15 mg/mL. The relative standard deviations of migration time and peak areas for intra- and inter-batch were 〈 2.45% and 〈 2.26%, respectively. The recovery rate of this method was 96.3~97.2%. Conclusion This method provides some advantages in separation speed, testing sensitivity, and operating convenience, with low sample and reagent consumption. The online sweeping-MEKC is an effective method for pharmacokinetic study and analysis on tracing biological samples.
出处 《Chinese Herbal Medicines》 CAS 2014年第1期53-57,共5页 中草药(英文版)
基金 Hebei Province Supporting Natural Science Fund(No.06276470)
关键词 1-O-acetylbritannilactone Inula britannica online sweeping-micellar electrokineticchromatography sesquiterpene lactone 1-O-acetylbritannilactone Inula britannica online sweeping-micellar electrokineticchromatography sesquiterpene lactone
  • 相关文献

参考文献1

二级参考文献16

  • 1叶姝,王书芳,瞿海斌,程翼宇.反向迁移毛细管胶束电动色谱分离测定复方丹参片中5种皂苷的含量[J].分析化学,2007,35(1):115-118. 被引量:14
  • 2Pessi A, Bianchi E, Chiappinelli L, et al. Application of capillary zone electrophoresis to the characterization of multiple antigen peptides [J]. J Chromatogr A, 1991, 557(1/2): 307-313.
  • 3Hansen H K, Hansen S H, Kraunsoe M, et al. Comparison of high-performance liquid chromatography and capillary electrophoresis methods for quantitative determination of glycyrrhizinic acid in pharmaceutical preparations [J]. EurJPharm Sci, 1999, 9: 41-46.
  • 4Velikinac I, Cudina O, Jankovic I, et al. Comparison of capillary zone electrophoresis and high performance liquid chromatography methods for quantitative determination of ketoconazole in drug formulations [J]. // Farmaco, 2004, 59: 419-424.
  • 5Gibson G, Ramstad T, Mills K A, et al. A method for the determination of minoxidil in hair-regrowth formulations by micellar electrokinetic capillary chromatography [J]. Ⅱ Farmaco, 2005, 60: 847-853.
  • 6Nemeth T, Jankovics P, N6meth-Palotas J, et al. Determination of paracetamol and its main impurity 4-aminophenol in analgesic preparations by micellar electrokinetic chromatography [J]. J Pharma Biomed Anal, 2008, 47: 746-749.
  • 7Ding X J, Li Y, Song B H. et al. Determination of 5'-mononucleotides in infant formula by capillary electrophoresis with ultraviolet detection [J]. Dairy Sci Technol, 2011, 91(6): 759-770.
  • 8Gel-Moreto N, Streich R, Galensa R. Chiral separation of six diastereomeric flavanone-7-O-glycosides by capillary electrophoresis and analysis of lemon juice [J]. J Chromatogr A, 2001, 925(1/2): 279-289.
  • 9Altria K D. Determination of drug-related impurities by capillary electrophoresis [J]. J Chromatogr A, 1996, 735(1/2): 43-56.
  • 10Altria K D, Kelly M A, Clark B J. Current applications in the analysis of pharmaceuticals by capillary electrophoresis II [J]. Trends Anal Chem, 1998, 17(4): 214-226.

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部