期刊文献+

某300MW机组一次调频性能分析及仿真 被引量:1

Performance analysis on primary frequency regulation for a 300MW unit and the verification
在线阅读 下载PDF
导出
摘要 基于对某300MW机组一次调频试验,分析了影响其一次调频性能的因素,汽轮机阀门流量函数与实际阀门流量特性不匹配以及机组的运行方式是造成机组一次调频性能不佳的主要原因。采用Matlab/Simulink软件建立了汽轮机及其调节系统模型,以验证试验结果的正确性,并提出了改善机组一次调频性能的建议。 On the basis of primary frequency regulation (PFR) on a 300 MW unit, the factors af- fecting performance of the PFR were analyzed. Mismatch between flow function of steam turbine valves and the actual flow characteristics,and the unit's operation mode were considered as the main factors causing poor performance of the unit's PFR. Thus, by employing the Matlab/Simu- link software, a model for the steam turbine and its governing system was established to verify the correctness of the conclusion. Furthermore,suggestions for improving the unit's PFR performance were put forward.
作者 盛锴
出处 《热力发电》 CAS 北大核心 2014年第4期119-123,共5页 Thermal Power Generation
关键词 300 MW机组 一次调频 汽轮机 调节系统 响应速度 阀门流量特性 仿真 300 MW unit primary frequency regulation steam turbine governor response speed flow characteristics simulation