摘要
提出了煤矿安全监控系统安装、使用、维护与管理要求:隔爆兼本质安全型防爆电源严禁设置在断电范围内,会造成局部通风机停电的调校应每半年1次,监控数据必须上传至矿务局(公司)、县(市)调度指挥中心等。提出了煤矿井下人员位置监测系统安装、使用与管理要求:各个人员出入井口应设置检测识别卡工作是否正常的装置,应设置人脸或虹膜等唯一性检测的装置,各个人员出入井口、重点区域出/入口、限制区域、巷道分支处等地点应设置人员位置监测分站等。
The paper put forward requirements of installation, use, maintenance and management of coal mine safety monitoring and control system. It proposed flameproof and intrinsically safe power supply is prohibited where power could be out off, adjustment which would cause power of local ventilators off should be done once every 6 months, and monitoring data must be uploaded to dispatching command center of mining bureau (company) or country (city). It put forward requirements of installation, use and management of underground personnel position monitoring system. It proposed devices should be equipped at each well head for personnel in or out to detect whether identification cards are normal as well as uniqueness detection based on face recognition or iris recognition, and personnel position monitoring substation should be installed at each well head for personnel in or out, exit and entrance in important area, restricted area, tunnel branch and other places.
出处
《工矿自动化》
北大核心
2014年第6期1-7,共7页
Journal Of Mine Automation
基金
国家自然科学基金重点项目(51134024)
国家高技术研究发展计划(863计划)资助项目(2012AA062203)
关键词
煤矿安全规程
安全监控
人员位置监测
coal mine safety regulation
safety monitoring and control
personnel position monitoring