期刊文献+

铸造三臂卡环在使用过程中基牙牙周膜的应力分析 被引量:1

Stress analysis of periodontal membrane of abutment teeth with three-arm casting clasp
在线阅读 下载PDF
导出
摘要 目的:研究不同倒凹深度的铸造三臂卡环在使用过程中基牙牙周膜所受的应力大小。方法:通过CBCT扫描下颌牙列,利用Mimics、Abaqus软件建立下颌第一磨牙缺失,以第二前磨牙和第二磨牙为基牙的活动义齿修复的三维有限元模型。实验分为六组:各组铸造三臂卡环进入倒凹深度分别为0.25mm、0.30mm、0.35mm、0.40mm、0.45mm和0.50mm。在有限元模型中,于义齿桥体中部垂直向下和向上逐渐加载,分别测定在义齿就位和脱位时各基牙牙周膜的应力变化。结果:义齿就位时的载荷(3.60±0.77 N)显著性地小于义齿脱位时的载荷(4.19±0.92N)(P<0.05);义齿就位和脱位时第二前磨牙基牙牙周膜承载的应力显著性大于第二磨牙(P<0.05);就位时基牙牙周膜应力较脱位时小(P<0.05)。结论:义齿就位时的载荷小于脱位时的载荷;义齿使用过程中第二前磨牙基牙牙周膜受到的应力大于第二磨牙的应力。 Objective: To investigate the stress distribution of the periodontal membranes (PDM) of the abutment teeth when applying three-ann cast clasp on the different undercut depths of the teeth. Methods: A three-dimensional finite element model of a removable partial denture system was established by scanning the mandible with CBCT, and using Mimics and Abaqus software. In the removable partial denture system, the mandibular first molars were missing and the second premolars and second molars were used as abutment. The experiment included six groups based on the depth of undercuts for the threearm casting clasps: 0.25mm, 0.30mm, 0.35mm, 0.40mm, 0.45mm, and 0.50mm. Vertical load was gradually placed downward and upward on the middle part of the occlusal surface of the denture in the model, and the stress distribution of the periodontal membranes surrounding the abutment teeth were measured during placement and removal of the denture. Results: The vertical load during placement (3.60±0.77 N) was significantly less than that during removal (4.19± 0.92N) (P〈0.05). The stress of the PDMs of the second molars was also less than that of the second premolars during placement and removal (P〈0.05). The stress during placement was also less than that during removal (P〈0.05). Conclusions: The load during placement of the denture was less than that during removal, and the stress on the PDMs of the second premolars was greater than that of the second molars during placement and removal.
出处 《口腔颌面修复学杂志》 2014年第3期149-152,共4页 Chinese Journal of Prosthodontics
关键词 卡环 牙周膜 有限元分析法 应力 clasp periodontal membrane finite element analysis stress
  • 相关文献

参考文献10

  • 1冯海兰,徐军.口腔修复学[M].北京:北京大学医学出版社,2010:29.
  • 2Souza JE, Silva NR, Coelho PG, et al. Retention strength of cobalt-chromium vs nickel-chromium titanium vs CP tita- nium in a cast framework association of removable partial overdenture[J]. J Contemp Dent Pract, 2011, 12(3): 179- 186.
  • 3王惠芸.我国人牙的测量和统计[J].中华口腔科杂志,1995,7(3):149-151.
  • 4苏忠平,何黎升,白石柱,商洪涛,毛赢,耿谦.应用Mimics和HyperMesh软件建立人体下颌骨三维有限元模型[J].实用口腔医学杂志,2012,28(2):192-195. 被引量:17
  • 5马达,唐亮,潘燕环.动态载荷下下前牙固定桥基牙牙周膜的三维有限元法分析[J].华西口腔医学杂志,2007,25(6):591-594. 被引量:13
  • 6Rekow ED, Harsono M, JanalM, et al. Factorial analysis of variables influencing stress in all-ceramic crowns [J]. Dent Mater, 2006, 22(2): 125-132.
  • 7王淑英,张振庭,白保晶.钴铬合金铸造三臂卡环固位臂宽度设计与基牙倒凹关系的三维有限元分析[J].中华口腔医学杂志,2007,42(5):276-279. 被引量:2
  • 8Aoda K,Shimamura I,Tahara Y, et al. Retainer design for unilateral extension base partial removable dental prosthesis by finite element analysis [J]. HYPER- LINK "http://www.ncbi.nlm.nih.gov/pubmed/20117068 \o "Journal of prosthodontic research." J Prosthodont Res 2010, 54(2): 84-91.
  • 9Mahmoud AAA, Wakabayashi N, Takahashi H. Prediction of permanent deformation in cast clasps for denture prosthe- ses using a validated nonlinear finite element modle[J]. Dent Mater,2007, 23(3): 317-324.
  • 10王宝成.现代牙科铸造技术[M].西安:世界图书出版公司西安公司,2000.20-90.

二级参考文献31

共引文献36

同被引文献2

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部