摘要
油田采出水经光电催化氧化法处理后,有机物和油被充分降解,用离子色谱法测定 NO3-、PO3-4,5次测定结果的 RSD为3.1%~5.8%。该方法测定出水中 NO3-、PO3-4质量浓度可代表除油处理后原水中总氮、总磷质量浓度,与分光光度法测定原水中总磷、总氮的结果相比,重现性好、耗时少。
Oilfield produced water was treated by photo catalytic oxidation,in which organic matter an d oil was fully degradated,NO3-and PO3 -4 were determined by ion chromatography.The results showed that the RSDs were 3 .1% and 5 .8% respectively by 5 times determinations.Ion chromatography method for determination of NO3-and PO3 -4 concentration could represent concentration of total nitrogen and total phosphorus in raw water. Compared with spectrophotometric method,it showed good reproducibility,less time-consuming.
出处
《环境监测管理与技术》
2014年第3期41-43,59,共4页
The Administration and Technique of Environmental Monitoring
基金
"光电催化氧化技术的工程应用研究"基金资助项目(CNOOC-KJ 125 ZDXM 26 TJY 02 TJY 2013-02)
关键词
总氮
总磷
光电催化氧化法
离子色谱法
油田采出水
Total nitrogen
Total phosphorus
Photoelectro catalytic oxidation
Ion chromatography
Oil-field produced water