摘要
结合现腈纶废水处理工艺应用中的问题 ,提出了混凝 两相厌氧 缺氧 好氧处理腈纶废水的工艺流程 ,该流程COD去除率 78%~ 82 % ,BOD去除率 95%~ 98% ,总氮去除率 60 %~ 65% ,EDTA去除率 75%~ 85% ,最终出水COD 2 2 0~ 2 60mg/L ,BOD小于 15mg/L ,EDTA小于 2 5mg/L ,NH3-N ,S2 -
The removals of sulfate and nitrogen from polyacrylonitrile fiber wastewater by coagulation anaerobic anoxic aerobic process were studied in laboratory scale. By this process, fair removals of 78%~82%, 95%~98%, 60%~65%, 75%~85% for COD, BOD, total nitrogen and EDTA respectively have been obtained. In the effluent the levels of COD, BOD and EDTA are in the sphere of 220~260 mg/L, less than 15mg/L and less than 25mg/L respectively and the NH 3—N and S 2- are not detectable.
出处
《给水排水》
CSCD
北大核心
2001年第6期40-44,共5页
Water & Wastewater Engineering