期刊文献+

新型推板式左心辅助血泵的体外模拟试验 被引量:1

In Vitro Mock Test of the New Push-Plate Left Ventricular Assist Device
在线阅读 下载PDF
导出
摘要 【目的】评价可变频率模式运行下的推板式左心血泵的体外模拟试验。【方法】在模拟台上 ,分别以可变频率模式和固定频率模式运行推板血泵 ,先后改变充盈压和主动脉压 ,记录泵输出量和搏动频率 ,比较两种模式的血泵性能。【结果】可变频率模式下的推板血泵能根据回心血流压力大小来控制搏动频率和泵输出量 ,比较符合生理特性。【结论】可变频率模式结构简单实用 ,运行可靠 ,性能优越 ,比固定频率模式和心电模式更先进。 Objective To evaluate the in vitro mock test of push-plate left ventricular assist device operated in variable rate mode. Methods The push-plate pump in mock loop was run in variable rate mode or fixed rate mode. The filling pressure and aorta pressure were adjusted respectively, and the pump output and rate were recorded. Pump performances of the two modes were compared. Results The push-plate pump run in variable rate mode could control its rate and output based on the filling pressure back to ventricle of heart, and better agree with physiological parameters. Conclusion The variable rate mode is simple in structure, reliable in running, perfect in performance, and is a more excellent mode than the fixed rate mode and the ECG mode.
出处 《中山医科大学学报》 CSCD 北大核心 2001年第4期251-253,279,共4页 Academic Journal of Sun Yat-sen University of Medical Sciences
基金 中山医科大学基金资助 (1995 )
关键词 辅助 左心室辅助装置 气动推板泵 体外模拟试验 assist circulation/instrument and equipment left ventricular assist devices push-plate pneumatic pump
  • 相关文献

参考文献3

二级参考文献3

  • 1吴敏,现代医学仪器与应用,1996年,2卷,11页
  • 2潘仕荣,中国生物医学工程学报,1996年,15卷,4期,1页
  • 3Chen Jifeng,Am Soc Artif Inter Organs Trans,1989年,35卷,398页

共引文献3

同被引文献18

  • 1Song XW,Wood HG.Computational Fluid Dynamics (CFD) Study of the 4th Generation Prototype of a Continuous Flow Ventricular Assist Device (VAD)[J].Transactions of the ASME,2004,126(4):180~187
  • 2Robbins RC,Barlow CW,Oyer PE,et al.Thirty years of cardiac transplantation at Stanford University[J].Journal of Thoracic and Cardiovascular Surgery,1999,117(5):939~949
  • 3Korfer R,El-Banayosy A,Arusoglu L,et al.Temporary pulsatile ventricular assist devices and biventricular assist devices[J].Ann Thorac Surg,1999,68(2):678~685
  • 4Hedlund KD,Atributeto F.AII britten Jr:Origin of the left ventricular vent during the early years of open heart surgery with the Gibbon heart lung machine[J].Tex Heartlnst J,2001,28(4):292~296
  • 5FouAA.John H:Gibbon[J].Tex Heart Inst J,1997,24(1):1~8
  • 6Denni CA.heartlung machine for openheart operation:How it came about[J].ASAIO Transections,1989,35(4):767~777
  • 7Cooley DA,Frazier OH.The past 50 years of Cardiovasular surgery[J].Circulation,2000,102(4):87~93
  • 8Tsutsui T,Nose Y.Arterial pressure pulsation during nonpulsatile biventricular bypass experiments:Possible idioperipheral pulsation.Artif Organs,1986,10(2):153~ 155
  • 9DeBakey ME.The odyssey of the artificial heart[J].Artif Organs,2000,24(6):405~411
  • 10Poirier VL.World wide experience with the TCI HeartMate system:Issues and future perspective[J].Thorac Cardiovasc Surg,,1999,47(2):316~320

引证文献1