摘要
通过压力降试验,指出自转清洗纽带开孔对流体阻力的影响,并计算出阻力系数,提出在电厂凝汽器中自转清洗纽带开孔面积比率的建议。
Through pressure drop tests, the effects of automatic cleaning twisted stripe with hole on fluid resistance are pointed out. The resistance coefficients are calculated. The hole-area ratio of automatic cleaning twisted stripe in the condenser in power plant is proposed.
出处
《电站系统工程》
北大核心
2001年第5期277-279,共3页
Power System Engineering
基金
湖南省教委2000年重点课题
关键词
自转清洗纽带
汽轮机
凝汽器
污垢
阻力特性
电厂
automatic cleaning twisted stripe
pressure drop characteristics
power plant