期刊文献+

高氯离子废水化学需氧量分析方法的研究 被引量:31

Analytical method of chemical oxygen demand in wastewater containing high chloride
在线阅读 下载PDF
导出
摘要 提出一种测定高氯离子废水 COD的新方法。其消解条件与现行国标法基本相同 ,消解过程产生的氯气用Na OH吸收并测定出氯离子的 COD校正值。由表观 COD值减去氯离子的 COD校正值 ,即为水样的真实 COD值。标样的相对误差在 -1.5 %~ 5 %之间 ,RSD%≤ 5 .5 %。高氯废水的 RSD%≤ 8.0 %。 A method was developed to eliminate chlorine interferences while analyzing COD i n wastewater The digestion conditions of the method were same as the national standard method The free chlorine produced in digestion procession was purged and absorbed into NaOH solutions The absorbed chlorine was analyzed to determi ne the chlorine compensated value The COD value was obtained by deducting the chlorine compensated value from apparent COD The relatively error of standards ranged from -1 5% to 5% with relatively standard deviation below 5 5% The analytical results of waster containing high chlorid showed that relatively stan dard deviation below 8 0%
出处 《中国环境监测》 CAS CSCD 北大核心 2002年第3期21-25,共5页 Environmental Monitoring in China
关键词 化学需氧量 COD 高氯离子废水 水质监测 COD analysis wastewater containing high chlorid
  • 相关文献

参考文献3

二级参考文献4

  • 1陶大钧.谈谈化学需氧量的测定[J].环境监测管理与技术,1989,1(1):41-45. 被引量:1
  • 2黄彩海 梅丽娟.高压蒸汽消化法测定废水的化学需氧量[J].中国环境监测,1987,3(2):32-32.
  • 3国家环保局《水和废水监测分析方法》编写组.水和废水监测分析方法(第3版)[M].北京:中国环境科学出版社,1989.354-356.
  • 4陶大钧.半微量快速烘箱法测定化学耗氧量[J].给排水技术,1983,(1):30-30.

共引文献57