期刊文献+

三维伪连续动脉自旋标记灌注成像与正电子发射计算机断层显像在脑部病变诊断中的比较 被引量:8

Comparison of 3D Pseudo-continuous Arterial Spin Labeling and Positron Emission Tomography-computed Tomography in the Brain Disorders
在线阅读 下载PDF
导出
摘要 目的比较三维伪连续动脉自旋标记灌注成像(3D-pCASL)与氟代脱氧葡萄糖及蛋氨酸正电子发射计算机断层显像(PET/CT)在脑部病变诊断中的一致性。方法对7例脑部病变患者进行3D-pCASL成像及PET/CT显像,视觉评定两者的一致性。结果 4例肿瘤性病变3D-pCASL均为高灌注,PET/CT均为高代谢。1例炎性脱髓鞘病变和1例代谢性脑白质病变3D-pCASL为高灌注,1例感染性病变3D-pCASL为低灌注,此3例非肿瘤性病变PET/CT均为高代谢。结论3D-pCASL可以无创性活体评估脑部病变的灌注状态,与PET/CT具有较好诊断一致性。 Objective To evaluate the diagnostic agreement of 3 D pseudo-continuous arterial spin labeling (3D-pCASL) and 18F-fluorodeoxyglucose and 11C-Methionine positron emission tomography-computed tomography (PET/CT) for brain disorders.Method 3 D-pCASL and PET/CT were performed on 7 patients with different brain disorders,and the diagnostic agreement was assessed by visual observation.Results Four tumor lesions presented hyperperfusion on 3D-pCASL,and hypermetabolism on PET/CT.One demyelinated lesion and one metabolic lesion showed hyperperfusion on 3D-pCASL,and one infected lesion showed hypoperfusion on 3D-pCASL; all these three lesions showed hypermetabolism on PET/CT.Conclusion 3D-pCASL can non-invasively evaluate the perfusion state of the brain disorder in vivo and have a good dignostic consistency with PET/CT.
出处 《中国医学科学院学报》 CAS CSCD 北大核心 2014年第4期377-384,共8页 Acta Academiae Medicinae Sinicae
基金 国家自然科学基金(81171319) 中国人民解放军总医院苗圃基金(13KMM41)~~
关键词 动脉自旋标记 灌注成像 正电子发射计算机断层摄影 arterial spin labeling perfusion weighted imaging positron emission tomography-computed tomography
  • 相关文献

参考文献20

  • 1Detre JA,Leigh JS,Williams DS,et al.Perfusion imaging[J].Magn Reson Med,1992,23(1):37-45.
  • 2Parkes LM,Rashid W,Chard DT,et al.Normal cerebral perfusion measurements using arterial spin labeling:reproducibility,stability,and age and gender effects[J].Magn Reson Med,2004,51(4):736-743.
  • 3Amann M,Achtnichts L,Hirsch JG,et al.3D GRASE arterial spin labelling reveals an inverse correlation of cortical perfusion with the white matter lesion volume in MS[J].Mult Scler,2012,18(11):1570-1576.
  • 4Jarnum H,Steffensen EG,Knutsson L,et al.Peffusion MRI of brain tumours:a comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imaging[J].Neuroradiology,2010,52(4):307-317.
  • 5Alsop DC,Detre JA.Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow[J].J Cereb Blood Flow Metab,1996,16(6):1236-1249.
  • 6Wang JJ,Zhang Y,Wolf RL,et al.Amplitude-modulated continuous arterial spin-labeling 3.0 T perfusion MR imaging with a single coil:feasibility study[J].Radiology,2005,235 (1):218-228.
  • 7Garcia DM,Duhamel G,Alsop DC.Efficiency of inversion pulses for background suppressed arterial spin labeling[J].Magn Reson Med,2005,54(2):366-372.
  • 8Dai W,Gareia D,de Bazelaire C,et al.Continuous flowdriven inversion for arterial spin labeling using pulsed radio frequency and gradient fields[J].Magn Reson Med,2008,60 (6):1488-1497.
  • 9Herscovitch P,Raichle ME.What is the correct value for the brain-blood partition coefficient for water?[J].J Cereb Blood Flow Metab,1985,5(1):65-69.
  • 10Kim SG.Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique:application to functional mapping[J].Magn Reson Med,1995,34(3):293-301.

同被引文献54

引证文献8

二级引证文献145

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部