摘要
目的:建立HPLC法测定异烟肼维B6片中异烟肼、维生素B6含量的方法。方法:采用Agilent Eclipse Plus C18(250mm×4.6 mm,5μm)色谱柱,以0.1%三乙胺溶液(加入20 mg辛烷磺酸钠,用磷酸调节pH至3.0±0.05)-甲醇(70∶30)为流动相,进样量为10μl,检测波长为291nm,流速为1.0 ml·min-1,柱温为30℃。结果:异烟肼、维生素B6分别在2.535~50.70μg(r=1.000 0)、0.136 8~2.735μg(r=1.000 0)范围内线性关系良好,平均回收率分别为99.57%(RSD=0.89%)、99.59%(RSD=0.43%)(n=9)。结论:本法专属性强、结果准确、灵敏、操作简便,可用于本品的质量控制。
Objective: To establish a determination method for isoniazid and vitamin B6 tablets by HPLC. Methods: The procedure was performed on an Agilent Eclipse Plus C18( 250 mm ×4.6 mm,5 μm) column at 30℃ and the detection wavelength was 291 nm. The mobile phase was composed of 0. 1% triethylamine [in which 20 mg sodium 1-octanesulfonate was added and the pH value was adjusted to( 3. 0 ± 0. 05) by phosphoric acid]and methanol( 70∶ 30) at a flow rate of 1. 0 ml·min- 1,and the injection volume was 10 μl. Results: The linear range of isoniazid and vitamin B6 was within the range of 2. 535-50. 700 μg( r = 1. 000 0) and 0. 137-2. 735 μg( r = 1. 000 0),respectively. The mean recovery was 99. 57%( RSD = 0. 89%) and 99. 59%( RSD = 0. 43%)( n = 9),respectively. Conclusion: The method is specific,accurate,sensitive and simple,which is applicable in the quality control of isoniazid and vitamin B6 tablets.
出处
《中国药师》
CAS
2014年第9期1510-1512,共3页