摘要 目的探讨临床常规血小板(PLT)计数不准确的原因,并提出纠正措施。方法收集PLT计数异常标本180例,分为4组,分别为低值PLT组(PLT≤20×109/L)72例,小红细胞组54例,大PLT组33例,PLT聚集组21例,分别采用光学法(PLT-O)、阻抗法(PLT-I)、手工镜检法(PLT-M)3种方法同时计数PLT,用配对t检验进行分析。结果低值PLT组、小红细胞组、大PLT组光学法与PLT计数PLT-M法比较差异无统计学意义(P>0.05),而PLT-I法与PLT-M法PLT计数比较差异有统计学意义(P<0.05)。PLT聚集组的标本,PLT-I法和PLT-O法计数结果比较,PLT-O法结果更接近真实值。结论 PLT-I法PLT计数的影响因素很多,主要有小红细胞干扰导致计数偏高,大PLT漏检导致PLT结果偏低,PLT聚集等,当PLT计数结果异常时应根据复检规则复检,采用手工PLT-M法或者PLT-O法纠正,必要时重新采血测定。 Objective To investigate the inaccurate causes of platelet(PLT)count and to propose the correcting measures.Meth-ods 180 specimens of abnormal PLT count were collected and divided into 4 groups:low PLT count group (PLT ≤20×109/L,72 cases),microcyte group(54 cases),large platelets group(33 cases)and platelet aggregation group(21 cases).The PLT count was simultaneously performed by using the three ways of the optical method (PLT-O),impedance method (PLT-I)and manual micros-copy method (PLT-M).The detection results were analyzed by the paired t test.Results The PLT count in the low PLT group, microcyte group and large platelets group had no statistical differences between PLT-O and PLT-M(P 〉0.05),and had statistical differences between the PLT-I and PLT-O(P 〈0.05).The PLT count of PLT-O in the platelet aggregation group was more close to actual value than that of PLT-I(P 〈0.05).Conclusion The PLT count by PLT-I has many influencing factors,which are mainly the microcytes interference leading to higher PLT count,missed detection of large PLT leading to lower PLT count,PLT aggrega-tion,etc.When the PLT count appears abnormal,the re-detection should be conducted according to the re-detection regulation, which can be corrected by adopting PLT-M or PLT-O,in necessity,the blood specimen could be re-collected for detection.
出处 《国际检验医学杂志》 CAS 2014年第20期2816-2817,共2页 International Journal of Laboratory Medicine
关键词 血小板计数 光学法 影响因素 复检规则 platelet count optical method influencing factors re-detection regulation
  • 相关文献

参考文献4

  • 1Kunicka JE, Fischer G,Murphy J, et al. Improved platelet count-ing using two-dimensional laser light scatter[J]. Am J Pathol,2000,114(2):283-289.
  • 2Harrison P,Horton A,Grant D,et al. Immunoplatelet counting:aproposed new reference procedure [J]. Br J Haematol, 2000, 108(2):228-235.
  • 3Barnes PW,Mcfadden SL,Machin SJ,et al. The international con-sensus group for hematology review: suggested criteria for actionfollowing automated CBC and WBC differential analysis[J]. LabHematol,2005 ,11(2) :83-90.
  • 4Sysmex XE-2100自动血细胞分析和白细胞分类的复检规则探讨[J].中华检验医学杂志,2008,31(7):752-757. 被引量:104

二级参考文献10

共引文献103

同被引文献31

引证文献2

二级引证文献5