期刊文献+

超(超)临界直流锅炉蓄热系数计算 被引量:10

Calculation of Heat Storage Coefficient for Ultra Supercritical Once-through Boilers
在线阅读 下载PDF
导出
摘要 给出了超(超)临界直流锅炉蓄热系数的计算方法:首先根据水和水蒸气的热力性质,通过程序计算出水冷壁中各相态段的长度,然后依据体积守恒方程、质量守恒方程和能量守恒方程分别计算水冷壁和过热器的蓄热系数.以某660 MW超超临界直流锅炉为例,利用锅炉设计数据计算得到4个工况下水冷壁和过热器的蓄热系数.结果表明:锅炉的蓄热系数为60 s左右,水冷壁蓄热系数占锅炉蓄热系数的15%~30%,过热器蓄热系数占锅炉蓄热系数的70%~85%. A calculation method has been proposed for heat storage coefficient of ultra supercritical once- through boilers. First, the length of each phase state in the water wall is calculated by program based on thermodynamic properties of the water and steam. Second, the mass, volume, and energy balance equa- tions are used to obtain the heat storage coefficient of both the water wall and superheater. Taking a 660 MW ultra supercritical power plant as an example, heat storage coefficients of the water wall and super- heater were respectively calculated at four different loads using design data of the boiler. Calculation re- suits show that the boiler's heat storage coefficient is about 60 s, in which the water wall accounts for 15%- 30%, and the superheater accounts for 70%-85%.
出处 《动力工程学报》 CAS CSCD 北大核心 2015年第3期173-177,共5页 Journal of Chinese Society of Power Engineering
关键词 超(超)临界直流锅炉 水冷壁 过热器 蓄热系数 ultra supercritical once-through boiler water wall superheater heat storage coefficient
  • 相关文献

参考文献6

二级参考文献22

  • 1刘吉臻,田亮,曾德良,刘鑫屏.660MW机组负荷-压力非线性特性的分析[J].动力工程,2005,25(4):533-536. 被引量:73
  • 2李旭.过热汽温的动态特性与控制[J].动力工程,2007,27(2):199-203. 被引量:32
  • 3林宗虎,锅内过程,1989年
  • 4章臣樾,锅炉动态特性及其数学模型,1987年
  • 5熊光愣,数字仿真算法与软件,1991年
  • 6郭喜燕,杨勇平,王修彦,杨志平.锅炉蓄热过程对机组煤耗的影响分析[J].中国电机工程学报,2007,27(26):30-34. 被引量:17
  • 7范永胜.600MW超临界机组直流锅炉的全工况建模与仿真研究[D].南京:东南大学,1997.
  • 8w·瓦格纳,A·克鲁泽.水和蒸汽的性质[M].北京:科学出版社,2003.
  • 9上海发电设备成套设计研究院.电站锅炉水动力计算方法标准[M].北京:机械工业出版社,1995:35.
  • 10李家川.基于机理建模的超临界机组一次调频的研究[D]华北电力大学(河北),2009.

共引文献65

同被引文献100

引证文献10

二级引证文献31

相关作者