期刊文献+

含风电场的受端系统暂态电压稳定性评估 被引量:27

Transient voltage stability assessment of receiving end grid incorporating with wind farm
在线阅读 下载PDF
导出
摘要 考虑风电场的自身特性和受端系统的结构特点,对含双馈风电场的受端系统暂态电压稳定性进行了评估。从严重度和可能性的角度提出了电压严重度和故障极限切除时间两个衡量暂态电压稳定性的指标。以所提指标为基础,重点考虑风速扰动和故障扰动的因素,研究了故障点位置、风电穿透率与受端系统暂态电压稳定之间的定性关系,并量化了暂态电压失稳的风险。在DIg SILENT/Power Factory仿真平台中搭建的含风电场的受端系统算例评估结果验证了所提方法的有效性。 Considering the characteristics of wind farm and the structural features, receiving-end grid, the transient voltage stability of receiving-end grid incorporating with doubly-fed wind farm is evaluated. This paper proposes two indexes which are voltage severity and critical clearing time to evaluate transient voltage stability from the perspective of severity and possibility. Based on the proposed indexes, the qualitative relationship between fault point location, wind power penetration rate and transient voltage stability of receiving end grid considering wind speed disturbance and fault disturbance is studied and instability risk of transient voltage is quantified. Results of assessment for receiving end grid incorporating wind farm built in DIgSILENT/PowerFactory simulation platform verify the effectiveness of the proposed method.
出处 《电力系统保护与控制》 EI CSCD 北大核心 2015年第13期8-14,共7页 Power System Protection and Control
基金 国家863计划项目(2012AA051703) 上海市科学技术委员会(13DZ2251900 10DZ2273400) 上海市科技攻关计划项目(14DZ1200905)~~
关键词 风电场 受端系统 暂态电压稳定指标 故障极限切除时间 失稳风险 wind farm receiving-end grid transient voltage stability index critical clearing time instability risk
  • 相关文献

参考文献13

二级参考文献129

共引文献673

同被引文献390

引证文献27

二级引证文献211

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部