期刊文献+

X射线通信系统的误码率分析 被引量:8

Bit error rate analysis of X-ray communication system
原文传递
导出
摘要 基于栅极控制脉冲发射X射线源与单光子探测技术的X射线通信语音方案已经在实验室实现,为探索未来X射线深空通信应用打下了坚实的基础.实验室X射线语音通信演示系统实现后,迫切需要测试X射线通信系统的误码率性能.在泊松噪声模型下对X射线通信演示系统的理论分析的基础上,使用基于现场可编程门阵列的误码率测量方法对开关键控调制方式下X射线通信误码率进行测量.通过实验测量发现,要实现语音通信,系统误码率应该达到10-4量级;分析、测量了现有系统在开关键控调制方式下不同速率对应的误码率,论证了泊松噪声模型理论分析现有X射线通信系统的合理性;分析提出了限制现有实验室条件下X射线通信误码率性能的主要因素. X-ray communication, which was firstly introduced by Keithe Gendreau in 2007, is potential to compete with conventional communication methods, such as microwave and laser communication, against space surroundings. As a result, a great deal of time and effort has been devoted to making the initial idea into reality in recent years. Eventually, the X-ray communication demonstration system based on the grid-controlled X-ray source and microchannel plate detector can deliver both audio and video information in a 6-meter vacuum tunnel. The point is how to evaluate this space X-ray demonstration system in a typical experimental way. The method is to design a specific board to measure the relationship between bit-error-rate and emitting power against various communicating distances. In addition, the data should be compared with the calculation and simulation results to estimate the referred theoretical model. The concept of using X-ray as signal carriers is confirmed by our first generation X-ray communication demonstration system. Specifically, the method is to use grid-controlled emission source as a transceiver while implementing the photon counting detector which can be regarded as an important orientation of future deep-space X-ray communication applications. As the key specification of any given communication system, bit-error-rate level should be informed first. In addition, the theoretical analysis by using Poisson noise model also has been implemented to support this novel communication concept. Previous experimental results indicated that the X-ray audio demonstration system requires a 10^-4 bit-error- rate level with 25 kbps communication rate. The system bit-error-rate based on on-off keying (0OK) modulation is calculated and measured, which corresponds to the theoretical calculation commendably. Another point that should be taken into consideration is the emitting energy, which is the main restriction of current X-ray communication system. The designed experiment shows that the detected X-ray energy is 7×10^-5 mW/m^2. This relatively low power level not only restricts the bit rate of transceiver, but also increases the error fraction to some extent. Obviously, OOK modulation can meet the high communication rate and relatively low bit-error-rate requirement of current audio demo system. Current restriction has been pointed out and the potential improvement is also presented.
出处 《物理学报》 SCIE EI CAS CSCD 北大核心 2015年第12期115-119,共5页 Acta Physica Sinica
基金 国家自然科学基金(批准号:11103069 61471357)资助的课题~~
关键词 X射线通信 泊松噪声模型 误码率 单光子探测器 X-ray communication, Poisson noise model, bit error rate, photon counting detector
  • 相关文献

参考文献9

  • 1Bass M 2010 Handbook of Optics (3rd Ed.) (Columbus: The McGraw-Hill Companies) p791.
  • 2张行勇 2012 空间X射线通信新方法提出 (北京: 中国科学报) 2012-1-19(4).
  • 3赵宝升, 吴川行, 盛立志, 刘永安 2013 光子学报 42 801.
  • 4邓宁勤, 赵宝升, 盛立志, 鄢秋荣, 杨灏, 刘舵 2013 物理学报 62 060705.
  • 5Qun F H, Brian M S, Zheng Y X 2009 Proc. SPIE 7464 74640H.
  • 6柯熙政, 席晓莉 2006 无线激光通信概论 (北京: 北京邮电大学出版社) 第173页.
  • 7王朋,赵宝升,盛立志,胡慧君,鄢秋荣.X射线脉冲星导航系统导航精度的研究[J].物理学报,2012,61(20):583-589. 被引量:9
  • 8赵明宇 2013 博士学位论文(北京:北京邮电大学).
  • 9胡慧君,赵宝升,盛立志,赛小锋,鄢秋荣,陈宝梅,王朋.用于脉冲星导航的X射线光子计数探测器研究[J].物理学报,2012,61(1):526-531. 被引量:12

二级参考文献5

共引文献18

同被引文献54

引证文献8

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部