摘要
文章结合实际工程经验,以110k V、220k V输电线路的典型杆塔作为研究对象。通过仿真软件建立三维模型,考虑单回、同塔双回及导线的相序等影响因素,对ADSS光缆挂点位置的空间电场进行了分析。结合沿ADSS光缆走向的场强分布及其他影响因素,为ADSS光缆选择合适悬挂点提出解决方法。
This paper combination with practical engineering experience takes typical tower of 110 k V, 220 k V power line on as the object of the research.The paper analyzes electric field around ADSS cable suspension point through 3D-calculation. In addition, single circuit, double circuits and Traverse phase-order are all concerned in this calculation. Combining electric field along ADSS cable and other factors, recommends the better suspend mode of ADSS.
出处
《电气技术》
2015年第5期30-34,共5页
Electrical Engineering