摘要 We introduce a corrected sinusoidal-wave drag force method (SDFM) into optical tweezers to calibrate the trapping stiffness of the optical trap and conversion factor (CF) of photodetectors. First, the theoretical analysis and experimental result demonstrate that the correction of SDFM is necessary, especially the error of no correction is up to 11.25% for a bead of 5μm in diameter. Second, the simulation results demonstrate that the SDFM has a better performance in the calibration of optical tweezers than the triangular-wave drag force method (TDFM) and power spectrum density method (PSDM) at the same signal-to-noise ratio or trapping stiffness. Third, in experiments, the experimental standard deviations of calibration of trapping stiffness and CF with the SDFM are about less than 50% of TDFM and PSDM especially at low laser power. Finally, the experiments of stretching DNA verify that the in situ calibration with the SDFM improves the measurement stability and accuracy. We introduce a corrected sinusoidal-wave drag force method (SDFM) into optical tweezers to calibrate the trapping stiffness of the optical trap and conversion factor (CF) of photodetectors. First, the theoretical analysis and experimental result demonstrate that the correction of SDFM is necessary, especially the error of no correction is up to 11.25% for a bead of 5μm in diameter. Second, the simulation results demonstrate that the SDFM has a better performance in the calibration of optical tweezers than the triangular-wave drag force method (TDFM) and power spectrum density method (PSDM) at the same signal-to-noise ratio or trapping stiffness. Third, in experiments, the experimental standard deviations of calibration of trapping stiffness and CF with the SDFM are about less than 50% of TDFM and PSDM especially at low laser power. Finally, the experiments of stretching DNA verify that the in situ calibration with the SDFM improves the measurement stability and accuracy.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第11期626-632,共7页 中国物理B(英文版)
基金 supported by the National Natural Science Foundation of China(Grant Nos.11302220,11374292,and 31100555) the National Basic Research Program of China(Grant No.2011CB910402)
关键词 optical tweezers trapping stiffness calibration conversion factor drag force method optical tweezers, trapping stiffness calibration, conversion factor, drag force method
  • 相关文献

参考文献33

  • 1Moffitt J R, Chemla Y R, Smith S B and Bustamante C 2008 Recent Advances in Optical Tweezers (Palo Alto: Annual Reviews) p. 205.
  • 2Guo H, Qu E, Xu C, Li Z, Cheng B and Zhang D 2007 Physics 36 476.
  • 3Xu C H, Guo H L, Qu E, Li Z L, Yuan M, Cheng B Y and Zhang D Z 2007 Chin. Phys. Lett. 24 2714.
  • 4Xia P, Zhou J H, Song X Y, Wu B, Liu X, Li D, Zhang S Y, Wang Z K, Yu H J, Ward T, Zhang J C, Li Y M, Wang X N, Chen Y, Guo Z and Yao X B 2014 J. Mol. Cell BioL 6 240.
  • 5Zhong M C, Wei X B, Zhou J H, Wang Z Q and Li Y M 2013 Nat. Commun. 4 1768.
  • 6Zhong M C, Gong L, Zhou J H, Wang Z Q and Li Y M 2013 Opt. Lett. 38 5134.
  • 7Zhong M C, Gong L, Li D, Zhou J H, Wang Z Q and Li Y M 2014 Appl. Phys. Lett. 105 181112.
  • 8Bishop A I, Nieminen T A, Heckenberg N R and Rubinsztein-Dunlop H 2004 Phys. Rev. Lett. 92 198104.
  • 9Shen G, Xue G, Cai J, Zou G, Li Y and Zhang Q 2013 Soft Matter 9 2512.
  • 10Xue G, Chen K, Shen G, Wang Z, Zhang Q, Cai J and Li Y 2013 Col- loid. Surf. A 436 1007.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部