期刊文献+

绝缘油中腐蚀性硫定量检测方法 被引量:2

Research on Quantitative Detection Method of Corrosive Sulfur in Insulating Oil
在线阅读 下载PDF
导出
摘要 介绍一种利用高效液相色谱定量检测绝缘油中腐蚀性硫(二苄基二硫)的方法,可为绝缘电气设备的状态评价提供更多依据.使用甲醇萃取和固相萃取两种样品前处理方法,可有效分离油样中的杂质,使二苄基二硫质量浓度在0~500 mg/L范围内线性良好,测量结果准确可靠,灵敏度较高,精密度好;但样品前处理回收率较低,具体试验条件还需进一步优化. A quantitative detection method of dibenzyl disulfide in corrosive sulfur in insulating oil by high performance liquid chromatography is introduced.h can provide more evidences for the state evaluation of insulation and electrical equipment.It can effectively separate the impurities from oil samples by these two sample pretreatment methods with methanol extraction and solid-phase extraction.The dibenzyl disulfide linearity in the range of 0mg/L-500mg/L is good,and the measurement results are accurate ,reliable ,high sensitivity and good precision ,but the recovery rate of the sample pretreatment methods is low, so the specific test conditions need to be further optimized.
出处 《山东电力技术》 2015年第12期50-54,共5页 Shandong Electric Power
关键词 腐蚀性硫 二苄基二硫(DBDS) 高效液相色谱(HPLC) 萃取 corrosive sulfur dibenzyl disulfide (DBDS) high performance liquid chromatography(HPLC ) extraction
  • 相关文献

参考文献7

二级参考文献31

  • 1凌愍,曾红.变压器油的静电性能及变压器油流静电试验方法[J].电网技术,1996,20(6):1-4. 被引量:8
  • 2LIPSHTEIN R S,SHAKHNOVISH M I. Transformer oil [M]. The Second Edition. Jerusalem:Israel Program for Scientific Translation, 1970.
  • 3ROCHA A H. Faults in 500 kV shunt reactors caused by corrosive sulfur in the insulation oil[C]//Proceedings of the Sixty-eight Annual International Conference of Double Clients. Boston:[s.n.],2001: 4-5.
  • 4HAJEK J, BENNSTAM G, DAHLUND M, et al. Quality of oil makes the difference, ABB discovers the solution to transformer breakdowns[J]. ABB Review, 2004(4): 61-63.
  • 5PREVOST T A. Review of test method to detect corrosive sulfur in insulation oil[C]//Weidmann-ACTI Inc. Sixth An- num Technical Conference.Petersburg: [s.n.],2007:12-14.
  • 6BENGTSSON C, DAHLUND M, HAJEK J, et al. Oil corrosion and conduting Cu2S deposition in power trans- former windings[C]//CIGRE Main Session.Paris: [s.n.], 2006:A2-111.
  • 7BOSS P. Presentation of CIGRE activities on power trans- formers [EB/OL]. http://www.cigre-a2.org/site/What/down- load/A2% 20presentation-boss_Aug_2009_v211D 10VER43 pdf, 2010-08-09.
  • 8MAINA R, SCATIGGIO F, KAPILA S, et al. Dibenzyl disulfide (DBDS) as corrosive sulfur contaminant in used and unused mineral insulationoils [EB/OL]. http://www.ci- gre-a2, org/Site/Publications/ download/DBDS_paper_Col- orVersionlD44VER52.pdf, 2010-08-09.
  • 9AMIMOTO T, NAGAO E, TANIMURA J,et al. Identifi- cation of affecting factors of copper sulfide deposition on insulating paper in oil[J]. IEEE Transactions on Di- electrics and Electrical Insulation, 2009, 16(1): 265-272.
  • 10SCATIGGIO F, TUMIATTI V, MAINA R, et al. Corro- sive sulfur in insulatiing oils: its detection and correlated power apparatus failures[J]. IEEE Transaction on Power Delivery, 2008, 23(1): 508-509.