期刊文献+

600MW机组湿式电除尘器工程调试与运行调整研究 被引量:3

600 MW wet electrostatic precipitator project commissioning and operation adjustment research
在线阅读 下载PDF
导出
摘要 研究广东省首台投产的600 MW机组湿式静电除尘器工程调试及投产后运行调整中存在的问题并加以解决,实现工程顺利投产,污染物排放满足国家环保要求。通过主导并参与广东珠海金湾发电有限公司3号机组湿式静电除尘器工程建设后期调试与投产后的运行调整,分析在此过程中存在的问题及其原因,并提出相应的技术改造及运行调措施。结果发现3号机组湿式静电除尘器顺利投产,烟尘、SO2、NOx排放浓度达到或低于燃气轮机组的现行排放限值,即:烟尘≤5 mg/m3、SO2≤35 mg/m3、NOx≤50 mg/m3。加装湿式静电除尘器后污染物排放符合环保政策规定及合同技术要求,实现大气污染物"近零排放"。 To study the Guangdong province the first production of 600 MW grade wet electrostatic precipitator project commissioning and put into operation after the operation adjustment and resolving the existent problem, to realize the project successfully put into production, chimney emissions meet the national environmental policy requirements. The dominant and participated in the Guangdong Zhuhai Jinwan Power Co. Ltd. unit 3 wet electrostatic precipitator construction debugging and put into operation after the operation adjustment, the analysis of the existing problems and their causes in the process, and put forward the corresponding technical transformation and operation measures. The No. 3 unit of wet electrostatic precipitator smooth operation, dust, sulfur di- oxide, nitrogen oxides emission concentration at or below the gas turbine's current emission limits, namely smoke is less than or equal to 5 mg/m3 and less than or equal to 35 mg/m3 , nitrogen oxides, sulfur dioxide is less than or equal to 50 mg/m^3. Wet electrostatic precipitator emissions to meet the requirements of environmental protection policies, to achieve near zero emissions of atmospheric pollutants.
出处 《电力科技与环保》 2016年第1期22-25,共4页 Electric Power Technology and Environmental Protection
关键词 湿式电除尘器 环保 节能减排 工程调试 运行调整 wet electrostatic precipitator environmental protection energy - saving and emission - reducing commissioning operation adjustment
  • 相关文献

参考文献7

二级参考文献18

  • 1黄延梅.GD型三电极管极式电除尘器的应用研究[J].重型机械,2006(z1):60-63. 被引量:1
  • 2黄三明.电除尘技术的发展与展望[J].环境保护,2005,33(7):59-63. 被引量:41
  • 3王智,贾莹光,祁宁.燃煤电站锅炉及SCR脱硝中SO_3的生成及危害[J].东北电力技术,2005,26(9):1-3. 被引量:56
  • 4Ahman R, Buekley W, Ray I. Wet electrostatic precipitation : demon- stration promise for fine particulate control: Part II [ J ]. Journal of Power Engineering,2001,105 ( 1 ) :42 - 44.
  • 5Huang Sheng Hsiu, Chert Chih Chieh. Loading characteristics of a miniature wire plate electrostatic precipitator[ J]. Aerosol science and technology,2003, ( 37 ) : 109 - 121.
  • 6闫克平.Electrostatic Precipitator: 1 l th International Conference on Electrostatic Precipitator[ M ]. 杭州:浙江大学出版社,2001.
  • 7Richard C Staehle,Ronald J Triscori.使用湿式电除尘器(WESP)收集湿法烟气脱硫(WFGD)后的酸雾和细小颗粒[C].中国围际脱硫脱硝技术与设备展览会暨技术研讨会.北京:2004.
  • 8Staehle R C,Triscori R J, Kumar K S, et al. Wet Electrostatic Precipi- tators for High Efficiency Control of Fine Particulates and Sulfuric Acid Mist[ C ]. Institute of Clean Air Companies Forum. Nashville, Tennessee :2003.
  • 9Li Lin,Chen Daren.Performance study of a DC-corona-based parti-cle charger for charge conditioning. Journal of Aerosol Science . 2011
  • 10薛建明,纵宁生.湿法电除尘器的特性及其发展方向[J].电力环境保护,1997,13(3):40-44. 被引量:33