期刊文献+

Box-Behnken响应面分析法对双阳极电Fenton法处理垃圾渗滤液工艺的优化 被引量:9

Optimization of electro-Fenton process for landfill leachate by Box-Behnken response surface methodological analysis
原文传递
导出
摘要 采用双阳极电Fenton法处理垃圾渗滤液,并在阴极曝气。应用Box-Behnken响应面分析法对电Fenton法处理的结果进行了优化,将Fe^(2+)投加量、电压、和反应时间3个因素进行实验设计,得到二次响应曲面模型。响应面分析表明,Fe^(2+)投加量与反应时间的交互作用对COD去除率影响最大,其次是电压与反应时间的交互作用。优化后的结果:Fe^(2+)投加量、电压、和反应时间分别为3 219.2 mg/L、6.11 V和180 min。模型方差分析得到F值和R2分别为24.2和0.977,说明该二次方程是显著的,模型在整个回归区域内拟合好,能够很好地反映电Fenton法处理垃圾渗滤液的过程。 Landfill leachate was treated by electro-Fenton technology. The Box-Behnken response surface analysis method was used to optimize landfill leachate treatment technology by the electro Fenton process. Three factors: Fe^(2+)dosing quantity,voltage,and reaction time,were studied in the Box-Behnken experimental design.The response surface model was determined by analyzing the response surface method results. The analysis showed that the interaction between Fe^(2+)dosing quantity and the reaction time had considerable influence on COD removal rate,followed by the voltage and reaction time interaction. The optimal results for Fe^(2+)dosing quantity,voltage,and reaction time were 3 219. 2 mg / L,6. 11 V,and 180 min,respectively. The variance analysis of the model showed that the F value and R^2 were 24. 2 and 0. 977,respectively,which meant that the quadratic equation was significant. The analysis of variance showed that the model was effective at simulating the treatment of landfill leachate by the electro Fenton method.
出处 《环境工程学报》 CAS CSCD 北大核心 2016年第4期1749-1754,共6页 Chinese Journal of Environmental Engineering
基金 国家自然科学基金资助项目(21276174) 山西省基础研究计划项目(2013011040-1 2008011020) 山西省高等学校科研项目(20090012)
关键词 垃圾渗滤液 电FENTON 响应面分析法 landfill leachate electro Fenton response surface method
  • 相关文献

参考文献14

  • 1李平,吴锦华,朱能武,吴平霄.Fenton法对老龄垃圾渗滤液难降解有机毒物的削减[J].环境工程,2012,30(1):39-42. 被引量:19
  • 2Klavarioti M. ,Mantzavinos D., Kassinos D. Removal of re- sidual pharmaceuticals from aquems systems by advanced oxidation processes. Environment International, 2009, 35 (2) :402-417.
  • 3Turro E. , Giannis A. , Cossu R. ,et al. Electrochemical oxi- dation of stabilized landfill leachate on DSA electrodes. Journal of Hazardous Materials,2011,190( 1-3 ) :460-465.
  • 4Cortez S. , Teixeira P. , Oliveira R. , et al. Mature landfill leachate treatment by denitrification and ozonation. Process Biochemistry ,2011,46( 1 ) : 148-153.
  • 5Poblete R. , Prieto-Rodrfguez L. , 011er I. , et al. Solar pho- tocatalytie treatment of landfill leachate using a solid miner- al by-product as a catalyst. Chemosphere, 2012,88 ( 9 ) : 1090-1096.
  • 6范拴喜,江元汝.Fenton法的研究现状与进展[J].现代化工,2007,27(z1):104-107. 被引量:47
  • 7Virkutyte J. , Jegatheesan V. Eleetro-Fenton, Hydrogenotro- phic and Fe2 ions mediated TOC and nitrate removal from aquaculture system:Different experimental strategies. Biore- source Technology, 2009,100 ( 7 ) : 2189-2197.
  • 8Panizza M. ,Cerisola G. Electro-Fenton degradation of syn- thetic dyes. Water Research, 2009,43 ( 2 ) :339-344.
  • 9班福忱,李亚峰,李慧星,贾新军,赵娜.电-Fenton法处理硝基苯废水的试验研究[J].现代化工,2006,26(z2):166-169. 被引量:5
  • 10吴彦瑜,周少奇,覃芳慧,赖杨岚,彭华平.响应面法优化Fenton处理难降解反渗透垃圾浓缩渗滤液[J].环境工程学报,2010,4(11):2494-2498. 被引量:33