期刊文献+

配电环网柜防潮控温系统的设计与实现 被引量:8

Design and Realization of the Moisture and Temperature Control System in Ring Main Units
在线阅读 下载PDF
导出
摘要 针对配电环网柜凝露的成因及对配电可靠性的影响,提出了基于多要素相互作用的配电环网柜的防凝露控制算法,并构建了配电环网柜防潮控温的远程实时集散监控系统。该系统有效保证了设备的安全稳定的运行,提高了自动化水平,减少了安全隐患。 In view of the cause of dew condensation in the ring main unit and the influence of the dew on the distribution reliability, this paper presents an anti-condensation algorithm for the ring main unit based on multi-factors and constructs a remote real-time distributed monitoring system for dehumidi- fication and temperature control of the ring main unit. The system proposed in the paper can effectively ensure the safe and stable operation of the equipment, improve the level of automation, reduce the security risks.
出处 《电网与清洁能源》 北大核心 2016年第8期67-72,共6页 Power System and Clean Energy
关键词 环网柜 凝露 控制算法 远程监控 ring main unit condensation control algorithm remote monitoring
  • 相关文献

参考文献12

二级参考文献16

共引文献21

同被引文献52

引证文献8

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部