Modeling and analysis for the image mapping spectrometer 被引量:1

Modeling and analysis for the image mapping spectrometer
在线阅读 下载PDF
导出
摘要 The snapshot image mapping spectrometer(IMS) has advantages such as high temporal resolution,high throughput,compact structure and simple reconstructed algorithm.In recent years,it has been utilized in biomedicine,remote sensing,etc.However,the system errors and various factors can cause cross talk,image degradation and spectral distortion in the system.In this research,a theoretical model is presented along with the point response function(PRF) for the IMS,and the influence of the mirror tilt angle error of the image mapper and the prism apex angle error are analyzed based on the model.The results indicate that the tilt angle error causes loss of light throughput and the prism apex angle error causes spectral mixing between adjacent sub-images.The light intensity on the image plane is reduced to 95%when the mirror tilt angle error is increased to ±100 "(≈ 0.028°).The prism apex error should be controlled within the range of 0-36"(0.01°)to ensure the designed number of spectral bands,and avoid spectral mixing between adjacent images. The snapshot image mapping spectrometer(IMS) has advantages such as high temporal resolution,high throughput,compact structure and simple reconstructed algorithm.In recent years,it has been utilized in biomedicine,remote sensing,etc.However,the system errors and various factors can cause cross talk,image degradation and spectral distortion in the system.In this research,a theoretical model is presented along with the point response function(PRF) for the IMS,and the influence of the mirror tilt angle error of the image mapper and the prism apex angle error are analyzed based on the model.The results indicate that the tilt angle error causes loss of light throughput and the prism apex angle error causes spectral mixing between adjacent sub-images.The light intensity on the image plane is reduced to 95%when the mirror tilt angle error is increased to ±100 "(≈ 0.028°).The prism apex error should be controlled within the range of 0-36"(0.01°)to ensure the designed number of spectral bands,and avoid spectral mixing between adjacent images.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第4期144-155,共12页 中国物理B(英文版)
基金 Project supported by the National Natural Science Foundation of China(Grant Nos.61635002 and 61307020) the Changjiang Scholars and Innovative Research Team in University(PCSIRT)Program,China
关键词 imaging spectrometers snapshot imaging spectrometer imaging model image mapper imaging spectrometers snapshot imaging spectrometer imaging model image mapper
  • 相关文献

同被引文献7

引证文献1

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部