期刊文献+

新型人工颈椎间盘山羊模型的建立及其研究 被引量:10

Establishment of Novel Artificial Cervical Disc Goat Model and Related Study
在线阅读 下载PDF
导出
摘要 目的观察新型国产人工颈椎间盘植入山羊体内后的效果,为其进一步的改进和临床应用提供实验基础。方法 12只雄性山羊,均行C_(3~4)新型国产人工颈椎间盘置换术。所有山羊于术前及术后不同时间点均行颈椎正侧位X线检查,测量C_(3~4)节段椎间高度(disc height,DH),椎间角(intervertebral angle,IVA)和脊柱功能单位(functional spinal unit,FSU)Cobb角,并进行统计学分析。结果所有实验山羊均成活,无伤口感染,未出现瘫痪。术后第2天,有一只山羊出现声音嘶哑,但1周后逐渐恢复正常。术前及术后不同时间点的C3~4节段椎间高度、IVA和FSU Cobb角的对比分析显示,差异均无统计学意义。结论新型国产人工颈椎间盘系统操作简便,实验动物术后并发症少,且较好的维持了目标节段椎间高度和颈椎生理曲度。 Objective To observe the effect of novel domestic-made artificial cervical disc in vivo with goat model,in order to provide an experimental basis for further improvement and clinical application.Methods 12 male experimental goats underwent C3-4 novel domestic-made artificial cervical disc replacement.All the goats were examined preoperatively and postoperatively on anteroposterior and lateral radiographs.The disc height (DH),intervertebral angle (IVA) and functional spinal unit (FSU) lordosis angle were measured and analyzed statistically.Results All experimental goats survived after operation,without incision infection and paralysis.Hoarseness occurred in one goat the second day after operation,and disappeared one week later.Statistical comparison in DH,IVA and FSU lordosis angle at C3-4 segment showed no significant difference among different time points.Conclusion Novel domestic-made artificial cervical disc system is easy to operate,has less complications,and can maintain the postoperative disc height and cervical spinal curvature well.
出处 《实用骨科杂志》 2017年第5期426-429,共4页 Journal of Practical Orthopaedics
基金 四川省科技支撑计划(2014SZ0236) 国家实用新型专利:一种人工椎间盘(ZL201120045610.5)
关键词 新型颈椎间盘假体 颈椎间盘置换 动物模型 动物实验 颈椎曲度 new cervical disc prosthesis cervical disc replacement animal model animal experiment cervical curvature
  • 相关文献

参考文献5

二级参考文献103

  • 1李鉴轶,朱青安,原林,赵卫东,林荔军,黄文华,吴旸.颈椎终板结构的生物力学研究[J].中华骨科杂志,2004,24(2):108-112. 被引量:24
  • 2郭永飞,陈德玉,徐建伟,王新伟,王良意,何志敏,陈宇,袁文,贾连顺.颈前路钛网植骨融合术后钛网沉陷的原因分析[J].中国脊柱脊髓杂志,2005,15(7):409-413. 被引量:43
  • 3Smith G W,Robinson R A. The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion[J]. J Bone Joint Surg Am, 1958,40-A: 607-624.
  • 4Cloward R B. The anterior approach for removal of ruptured cervical disks[J]. J Neurosurg, 1958,15 : 602-617.
  • 5Rieger A, Holz C, Marx T, Sanchin L, Menzel M. Vertebral autograft used as bone transplant for anterior cervical corpectomy: technical note[J]. Neurosurgery,2003,52 : 449-453.
  • 6Moore R J ,Osti O L, Vernon-Roberts B, Fraser R D. Changes in endplate vascularity after an outer anulus tear in the sheep [J]. Spine,1992,17:874-878.
  • 7Wilke H J, Kettler A,Claes L E. Are sheep spines a valid biomechanical model for human spines[J]? Spine, 1997,22 : 2365-2374.
  • 8Kandziora F, Pflugmacher R, Scholz M, Schnake K, Lucke M, Schroder R,et al. Comparison between sheep and human cervical spines : an anatomic, radiographic, bone mineral density, and biomechanical study [J]. Spine,2001,26:1028-1037.
  • 9Goffin J, Geusens E, Vantomme N, Quintens E, Waerzeggers Y, Depreitere B, et al. Long-term follow-up after interbody fusion ofthe cervical spine. J Spinal Disord Tech 2004;17:79-85.
  • 10Bohlman HH, Emery SE, Goodfellow DB, Jones PK. Robinson anterior cervical discectomy and arthrodesis for cervical radiculopathy. Long-term follow-up of one hundred and twenty-two patients. J Bone Joint Surg Am 1993;75: 1298-307.

共引文献31

同被引文献78

引证文献10

二级引证文献20