期刊文献+

HPLC-CAD法测定蛇胆汁中牛磺胆酸钠的含量 被引量:7

Determination of sodium taurocholate in snake bile by HPLC-CAD
原文传递
导出
摘要 目的:建立测定蛇胆汁中牛磺胆酸钠含量的高效液相色谱-电雾式检测器(HPLC-CAD)法,同时对紫外检测器、蒸发光检测器和电雾式检测器3种不同检测器的灵敏度进行比较。方法:采用ZORBAX SB C_(18)色谱柱(4.6 mm×250 mm,5μm),流动相为乙腈-0.1%三氟乙酸水(30∶70),等度洗脱,流速为1.0 mL·min^(-1),柱温35℃,CAD雾化温度35℃,气压4.206×10~5 Pa。结果:蛇胆汁进样量在0.174 2~3.484 0μg范围内与峰面积线性关系良好(r=0.999 5),平均回收率为99.0%,RSD为0.76%(n=6),阴性对照无干扰。本实验测得牛磺胆酸钠含量范围眼镜蛇科为5.69~28.85 mg·g^(-1);游蛇科为23.37~29.65 mg·g^(-1);蝰科为6.54~24.00 mg·g^(-1)。结论:该方法经方法学验证,可作为蛇胆汁质量控制的方法。 Objective: To establish an HPLC-CAD method for determination of Sodium taurocholate in snake bile, and to compare the sensitivity of three different detectors of ultraviolet detector ( UV ), evaporative light scattering detector( ELSD )and charged aerosol detector (CAD). Methods: ZORBAX SB CIs chromatographic column ( 4.6 mm ×250 mm,5μm ) was used; mobile phase was acetonitrile : 0.1% trifluoroacetic acid ( 30:70 ) at a flow rate of 1.0 mL. min^-1 ; the column temperature was 35℃ ; the detector was CAD ( the spray temperature was 35 ℃ ), at gas pressure of 4.206 × 10^5 Pa. Results: The snake bile showed good linear rang with 0.174 2-3.484 μg ( r=0.999 5 ) ; the average recovery was 99.0% ; RSD was 0.76% ( n=6 ) ; and the negative control had no interference. The measured contents of sodium taurocholate were 5.69-28.85 mg·g^-1 for Elapidaerang, 23.37- 29.65 mg·g^-1 for Colubridaeas, and 6.54-24.00 mg·g^-1 for Viperidaeas. Conclusion: The method can be used for the quality control of snake bile.
出处 《药物分析杂志》 CAS CSCD 北大核心 2017年第7期1223-1227,共5页 Chinese Journal of Pharmaceutical Analysis
基金 2015年安徽省科技攻关计划项目资助(1501041174)
关键词 检测方法比较 紫外检测器 蒸发光检测器 电雾式检测器 蛇胆汁 牛磺胆酸钠 comparison of detection methods UV ELSD CAD snake bile sodium taurocholate
  • 相关文献

参考文献14

二级参考文献134

共引文献54

同被引文献89

引证文献7

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部