摘要
高等学校的用电负荷具有一定的特殊性,由于用电负荷阶段性变化大和用电负荷区域性变化大,导致高校内部配电房的负荷备用容量过大。本文介绍一种通过低压侧配电系统适时并联的方法,调整高校内部动态负荷,降低整个校区的负荷备用容量,优化了配电系统,减少了电力变压器的空载损耗,提高了变压器的经济运行指标,更节能更环保。
The power consumption of colleges and universities has certain particularity that the load reserve capacity of internal distribution room in colleges and universities is too large due to the large phased change of electricity load and large regional variation of power load. This paper introduces a method of low voltage side of distribution sys- tem in a timely manner in parallel, which can adjust the internal dynamic load of university, reduce the load of spare capacity of the entire campus, to optimize the distribution system, reduce no-load loss of transformer, improve the transformer economic operation index, and become more energy-saving and more environmentally friendly.
出处
《日用电器》
2018年第4期50-52,共3页
ELECTRICAL APPLIANCES
关键词
人潮负荷
节能
经济运行
human tide load
energy saving
economic operation