期刊文献+

Validating a point of care lactate meter in adult patients with sepsis presenting to the emergency department of a tertiary care hospital of a low-to middle-income country 被引量:7

Validating a point of care lactate meter in adult patients with sepsis presenting to the emergency department of a tertiary care hospital of a low-to middle-income country
在线阅读 下载PDF
导出
摘要 BACKGROUND: Timely identifi cation of high blood lactate levels in septic patients may allow faster detection of those patients requiring immediate resuscitation. Point-of-care(POC) testing is being increasingly utilized in the emergency department(ED). We examined the accuracy and timesaving effect of a handheld POC lactate device for the measurement of fingertip and whole blood lactate as compared with reference laboratory blood testing in septic ED patients.METHODS: A convenience sample of adult ED patients receiving serum lactate testing were enrolled prospectively in the ED of a multidisciplinary tertiary care hospital serving the population of one of the major cities of Pakistan. Participants underwent fi ngertip POC lactate measurement with a portable device and simultaneous whole blood sampling for analysis by both the POC lactate device and standard laboratory method. Lactate measurements were compared by intraclass correlation(ICC) and Bland and Altman plots.RESULTS: Forty-three septic patients were included in the study. The fingertip POC & whole blood POC lactate measurements each correlated tightly with the reference method(ICC=0.93 & ICC=0.92, respectively). Similarly at 6 hours, the fingertip POC & whole blood POC lactate measurements demonstrated satisfactory correlation with the reference method(ICC=0.95 & ICC=0.97, respectively).CONCLUSION: Fingertip POC lactate measurement is an accurate method to determine lactate levels in septic ED patients.KEY WORDS: Sepsis; Point of care; Lactate; Emergency department; BACKGROUND: Timely identification of high blood lactate levels in septic patients may allow faster detection of those patients requiring immediate resuscitation. Point-of-care (POC) testing is being increasingly utilized in the emergency department (ED). We examined the accuracy and time- saving effect of a handheld POC lactate device for the measurement of fingertip and whole blood lactate as compared with reference laboratory blood testing in septic ED patients. METHODS: A convenience sample of adult ED patients receiving serum lactate testing were enrolled prospectively in the ED of a multidisciplinary tertiary care hospital serving the population of one of the major cities of Pakistan. Participants underwent fingertip POC lactate measurement with a portable device and simultaneous whole blood sampling for analysis by both the POC lactate device and standard laboratory method. Lactate measurements were compared by intraclass correlation (ICC) and Bland and Altman plots. RESULTS: Forty-three septic patients were included in the study. The fingertip POC & whole blood POC lactate measurements each correlated tightly with the reference method (ICC=0.93 & ICC=0.92, respectively). Similarly at 6 hours, the fingertip POC & whole blood POC lactate measurements demonstrated satisfactory correlation with the reference method (ICC=0.95 & ICC=0.97, respectively). CONCLUSION: Fingertip POC lactate measurement is an accurate method to determine actate levels in septic ED patients.
出处 《World Journal of Emergency Medicine》 CAS 2017年第3期184-189,共6页 世界急诊医学杂志(英文)
关键词 SEPSIS Point of care LACTATE Emergency department Pakistan Sepsis Point of care Lactate Emergency department Pakistan
  • 相关文献

参考文献1

二级参考文献3

共引文献1

同被引文献37

引证文献7

二级引证文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部