重症监护病房环境微生物学监测与空气消毒方法效果的研究 被引量:7

Study on environmental microbiology monitoring and air disinfection effect in Intensive Care Unit
原文传递
导出
摘要 目的了解重症监护病房空气不同消毒方法的效果,帮助制定个性化环境消毒方案。方法随机选择2014年1月-2017年3月某医院重症监护病房设作实验对象,按照不同时间段对重症监护病房空气环境微生物学分布情况进行监测,根据监测结果,调整消毒方案,分析重症监护病房空气消毒改善效果。结果实施消毒监管后,重症监护病房空气中的细菌总数明显降低。结论重症监护病房环境微生物学监测可以用于病房空气环境消毒方案的调整,从而改善病房消毒效果,避免致病菌的传播,对由空气传播的医院感染起到有效的控制作用。 Objective To understand the effect of different methods of air disinfection in the Intensive Care Unit by monitoring the microorganism in the environment,and to help the ward to formulate the individualized environmental disinfection scheme. Methods A hospital Intensive Care Unit was selected randomly from January 2014 to March 2017 as the experimental object,and the distribution of microbiology of the air environment in Intensive Care Unit was monitored according to different time periods. According to the results of the monitoring,the disinfection plan was adjusted,and the effect of improving the air disinfection in Intensive Care Unit was analyzed. Results Before and after the implementation of supervision,the number of bacteria in the Intensive Care Unit was significantly reduced. Conclusion Microbiology monitoring in Intensive Care Unit can be used to adjust the air environment disinfection plan of the ward,so as to improve the disinfection effect of the ward,avoid the transmission of pathogenic bacteria,and to control the airborne infection in the hospital. So it is worth popularizing and applying.
作者 许珍珍 陆登辉 XU Zhen - zhen;LU Deng - hui(Jingzhou Traditional Chinese Medicine Hospitial, Jingzhou Hubei 434000, Chin)
机构地区 荆州市中医医院
出处 《中国消毒学杂志》 CAS 2018年第5期355-356,359,共3页 Chinese Journal of Disinfection
关键词 重症监护病房 空气环境 微生物学 监测 空气消毒 Intensive Care Unit air environment microbiology monitoring air disinfection
  • 相关文献

参考文献9

二级参考文献58

  • 1郭丽珍,雷风仙,张丽平,赵小平,郭兵方,郭海霞.住院患者留置尿管目标性监测与分析[J].中华医院感染学杂志,2006,16(9):1009-1011. 被引量:56
  • 2鲍凤.我国医院室内空气消毒的研究进展[J].中国消毒学杂志,2006,23(6):564-566. 被引量:11
  • 3赵金镯,宋伟民.大气超细颗粒物的分布特征及其对健康的影响[J].环境与职业医学,2007,24(1):76-79. 被引量:42
  • 4国家技术监督局.GB/T162921996.医药工业洁净室(区)悬浮粒子、浮游菌和沉降菌的测试方法[M].北京:中国标准出版社,1996.
  • 5Brook RD. Is air pollution a cause of cardiovascular disease: updated review and controvercies[J]. Rev Environ Health, 2007,22:115-137.
  • 6赵淑妹.手术室护理人员手册[M].长沙:湖南科学技术出版社,2000.73-200.
  • 7Dettenkofer M,Ebner W,Els T,et al. Surveillance of Nosoco- mial Infections in a Neurology Intensive Care Unit[J]. J Neu- rology, 2001, 248(11) :959-964.
  • 8Rosenthal VD,Maki DG,Jamulitrat S. International Nosocomial Infection Control Consortium(INICC) report,data summary for 2003-2008,issued June 2009[J].Am J Indect Control,2010,(02):95-104.e2.
  • 9Nemec A. Multidrug resistant Acinetobacter baumannii[J].Kilin Mikrobiol Infekc Lek,2008,(05):162-177.
  • 10Ariza X,Castellote J,Lora-Tamayo J,et al.Risk factors for resistance to ceftriaxone and it's impact on mortality in community,healthcare and nosocomial spontaneous bacterial peritonitis[J].J Hepatol,2012,56(4):825-832.

共引文献65

同被引文献84

引证文献7

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部