期刊文献+

HPLC-MS/MS Determination of Oleandrin and Adynerin in Blood with Solid Phase Supported Liquid-Liquid Extraction

HPLC-MS/MS Determination of Oleandrin and Adynerin in Blood with Solid Phase Supported Liquid-Liquid Extraction
在线阅读 下载PDF
导出
摘要 [Objectives]To optimize the determination method of oleandrin and adynerin in blood. [Methods]High performance liquid chromatography-mass spectrometry( HPLC-MS/MS) was applied to determine oleandrin and adynerin in blood. The blood sample was dispersed and fixed on a solid phase supported liquid-liquid extraction column and eluted with ethyl acetate. The resulting eluent was used for chromatographic separation with Kinetex C_(18) column as the separation column and gradient elution was performed using 10 mmol/L ammonium formate solution containing 0. 1%( volume fraction) formic acid and acetonitrile as the mobile phase. In the tandem mass spectrometry analysis,the detection was carried out using the electrospray positive ion source multiple reaction monitoring mode. [Results] The mass concentration of oleandrin and adynerin showed linear relationship in the range of 2-100 μg/L. The limit of detection( 3 S/N) of the method was 0. 5 μg/L.A blank sample was used as the substrate for the spike recovery test. The recovery rate was in the range of 90. 0%-98. 0%,and the relative standard deviation( RSD) of the measured values( n = 6) was in the range of 2. 1%-7. 3%. [Conclusions]The method established in this experiment has the benefits of simple pretreatment,good recovery,high sensitivity and strong specificity,and is expected to provide an ideal method for the determination of such drugs in blood. [Objectives]To optimize the determination method of oleandrin and adynerin in blood. [Methods]High performance liquid chromatography-mass spectrometry( HPLC-MS/MS) was applied to determine oleandrin and adynerin in blood. The blood sample was dispersed and fixed on a solid phase supported liquid-liquid extraction column and eluted with ethyl acetate. The resulting eluent was used for chromatographic separation with Kinetex C(18) column as the separation column and gradient elution was performed using 10 mmol/L ammonium formate solution containing 0. 1%( volume fraction) formic acid and acetonitrile as the mobile phase. In the tandem mass spectrometry analysis,the detection was carried out using the electrospray positive ion source multiple reaction monitoring mode. [Results] The mass concentration of oleandrin and adynerin showed linear relationship in the range of 2-100 μg/L. The limit of detection( 3 S/N) of the method was 0. 5 μg/L.A blank sample was used as the substrate for the spike recovery test. The recovery rate was in the range of 90. 0%-98. 0%,and the relative standard deviation( RSD) of the measured values( n = 6) was in the range of 2. 1%-7. 3%. [Conclusions]The method established in this experiment has the benefits of simple pretreatment,good recovery,high sensitivity and strong specificity,and is expected to provide an ideal method for the determination of such drugs in blood.
出处 《Medicinal Plant》 CAS 2018年第3期5-8,共4页 药用植物:英文版
基金 Supported by Project of National Natural Science Foundation(81273346)
关键词 High performance liquid chromatography-mass spectrometry(HPLC-MS/MS) BLOOD Oleandrin Adynerin High performance liquid chromatography-mass spectrometry (HPLC-MS/MS) Blood Oleandrin Adynerin
  • 相关文献

参考文献8

二级参考文献124

共引文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部