期刊文献+

佛山地铁3号线镇安站主体围护结构设计合理性分析 被引量:2

The Rationality Analysis of the Design of the Main Bodyguard Structure of Zhen'an Station of Foshan Metro Line 3
在线阅读 下载PDF
导出
摘要 以佛山市轨道交通3号线镇安站为例,进行主体围护结构的设计和计算分析研究,通过对车站主体围护结构基坑的模拟分析计算,得出合理的结构受力体系,保证车站主体围护结构施工的安全稳定性。 Taking Zhen'an station of Foshan metro line 3 as an example, analyzes and researches the design and calculation of the main body of retaining structure, through simulation analyzing and calculating the foundation pit of the main body of the retaining structure, the reasonable structure stress system is conducted, to ensure the safety stability of the station main body construction of retaining structure.
作者 付叶能 FU Ye-neng(China Railway Major Bridge Reconnaissance & Design Institute Co.Ltd.,Rail Branch,Wuhan 430050,China)
出处 《工程建设与设计》 2018年第18期8-9,共2页 Construction & Design for Engineering
关键词 地铁 主体围护结构设计 基坑结构计算 施工工法 subway design of body retaining structure calculation of foundation pit structure construction method