摘要
建立电感耦合等离子体质谱法同时测定儿童洗涤护肤产品中铝、锑、砷、钡、硼、镉、铬、钴、铜、铅、锰、汞、镍、硒、锶、锡和锌17种有毒有害元素的方法。样品采用微波消解法处理,通过在线内标及碰撞反应池技术校正基体效应,并优化了仪器的工作参数。测定锌的线性范围为5~1 000μg/L,砷、镉、铬、汞的线性范围为0.5~100μg/L,其它12种元素的线性范围为1~200μg/L,相关系数均在0.999以上,方法检出限为1.0~25.7μg/kg。加标平均回收率为88.6%~103.2%,测定结果的相对标准偏差均小于5%(n=6)。该方法快速、简便、准确,可应用于儿童洗涤护肤产品中有毒有害元素的测定。
A method for simultaneous determination of 17 kinds of poisonous and harmful elements such as aluminum,antimony,arsenic,barium,boron,cadmium,chromium,cobalt,copper,lead,manganese,mercury,nickel,selenium,strontium,tin and zinc in children’s detergent and skin care products by inductively coupled plasma mass spectrometry was established.The samples were pretreated with microwave digestion.The matrix effect was corrected by the online internal standard and the collision reaction pool technique,and the working parameters of the instrument were optimized.The linear range was 5–1 000μg/L for Zn,0.5–100μg/L for As,Cd,Cr,Hg,and 1–200μg/L for other elements.The correlation coefficients were more than 0.999,the detection limits were 1.0–25.7μg/kg.The average recoveries were 88.6%–103.2%,and the relative standard deviations of detection results were less than 5%(n=6).This method is fast,simple and accurate,which can be applied to the determination of poisonous and harmful elements in children’s detergent and skin care products.
作者
黄让明
辛希奕
林于淳
施煜
朱虹
HUANG Rangming;XIN Xiyi;LIN Yuchun;SHI Yu;ZHU Hong(Guangdong Shantou Institute of Quality and Metrology Supervision Testing,Shantou 515041,China)
出处
《化学分析计量》
CAS
2018年第2期27-31,共5页
Chemical Analysis And Meterage
关键词
电感耦合等离子体质谱法
儿童洗涤护肤产品
有毒有害元素
inductively coupled plasma mass spectrometry
children’s detergent and skin care product
poisonous and harmful element