重整装置脱戊烷塔塔顶换热系统腐蚀原因及工艺防腐对策

CORROSION ANALYSIS AND PROCESS COUNTERMEASURES FOR THE HEAT EXCHANGE SYSTEM OF CATALYTIC REFORMING DEPENTANIZER
在线阅读 下载PDF
导出
摘要 针对中国石油某石化公司重整装置在运行过程中出现的脱戊烷塔顶空冷器、后冷器频繁结盐堵塞和腐蚀泄漏进行分析。通过对国内其他同类装置类似问题处理经验进行讨论,提出工艺防腐对策。 Analysis was carried out on the salt blockage and corrosion leakage frequently occurring in the overhead air cooler and after cooler of depentanizer in the catalytic reformer in some Petrochemical Company in CNPC.The experiences for dealing witli the similar problems in otlier domestic similar devices were discussed,and process anticorrosion countermeasures were put forward.
作者 董大清 张元礼 崔印强 邹本海 郑文博 Dong Daqing;Zhang Yuanli;Cui Yinqiang;Zou Benhai;Zheng Wenbo(Liaoyang Petrochemical Branch Co.,CNPC,Liaoyang Liaoning 111003;Liao Yang Branch Company of Northeast Refining&Chemical Engineering Ltd.Co.,CNPC,Liaoyang Liaoning 111003)
出处 《齐鲁石油化工》 2018年第4期305-307,共3页 Qilu Petrochemical Technology
关键词 重整装置 脱戊烷塔 腐蚀 对策 catalytic reforming unit depentanizer corrosion countermeasure