期刊文献+

术中实时超声在引导变形侧脑室穿刺术中的应用价值(附19例报告) 被引量:3

Real-time ultrasonography guided the puncture of deformed lateral ventricular during craniectomy:Report of 19 cases
在线阅读 下载PDF
导出
摘要 目的分析超声在实时引导变形移位侧脑室穿刺术中的应用价值。方法对19例重型颅脑损伤合并脑疝患者,术中利用超声实时引导进行侧脑室穿刺术。对这些患者的引流管到位以及相关并发症的发生情况作回顾性分析评估。结果 19例(100%)患者均成功置入侧脑室引流管,其中16例(84.2%)首次穿刺即成功置管,3例(15.8%)需再次穿刺;术后1例(5.3%)出现颅内感染并发症,无穿刺相关血肿。结论术中超声实时引导变形移位侧脑室穿刺,不仅安全有效,而且操作简便,值得推广应用。 Objective To analyze the value of ultrasonography in real-time guiding the puncture of deformed lateral ventricular during craniectomy. Methods In total,19 patients with severe craniocerebral injury and cerebral hernia,in which lateral ventricular puncture was performed with the guidance of ultrasonography, were collected and retrospectively analyzed the drainage tube placement and related complications postoperatively. Results In 19 cases (100%) patients drainage canal were successfully placed into the lateral ventricle, and the first successful puncture was made in 16 cases (84. 2%), while once more puncture in the other 3 cases. Related intracerebral infection was appeared in 1 cases (5.3%), without cerebral hemorrhage after puncture happened to anyone. Conclusion Real-time ultrasonography can well guide the puncture of deformed lateral ventricular during craniectomy, which is not only safe and effective,but also easy to operate.
作者 洪文瑶 赵建祥 王开宇 刘宇清 廖正俭 黄绳跃 HONG Wenyao;ZHAO Jianxiang;WANG Kaiyu;LIU Yuqing;LIAO Zhengjian;HUANG Shengyue(Departmentof Nuerosurgery,FujianProvincialHospital,Fuzhou,Fujian350001,China)
出处 《福建医药杂志》 CAS 2019年第2期16-19,共4页 Fujian Medical Journal
关键词 实时超声 术中引导 变形侧脑室 脑室穿刺 real-time ultrasonography intraoperative guidance deformed lateral ventricle lateral ventricular puncture
  • 相关文献

参考文献7

二级参考文献31

  • 1辛利平,孙彦辉,王蕾,谷喜音.B型超声实时定位在脑胶质瘤切除术中的应用[J].中国微侵袭神经外科杂志,2005,10(4):180-181. 被引量:14
  • 2陈运洪,王向宇,余力,柯以铨,徐如祥.改进超声技术在脑胶质瘤术中应用[J].中华神经医学杂志,2006,5(7):702-705. 被引量:13
  • 3杨立斌,贺伟旗,虞俊,杨文涛,匡永勤,顾建文.超声引导下脑室穿刺的临床应用研究[J].华西医学,2007,22(3):586-587. 被引量:2
  • 4Unsgaard G, Gronningsaeter A, Ommedal S, et al. Brain operations guided by real-time two-dimensional ultrasound: new possibilities as a result of improved image quality [ J ]. Neurosurgery, 2002, 51 ( 2 ) : 402 -412.
  • 5Mascott CR, Sol JC, Bousquel P, et al. Quanlification of true in vivo (application) accuracy in cranial image-guided surgery: influence of mode of patient registration [ J]. Neurosurgery, 2006, 59( 1 Suppl 1 ) : ONS146 - 156.
  • 6Wirtz CR, Tronnier VM, Bonsanto MM, et al. Neuronavigation. Method and prospects [ J ]. Nervenarzt, 1998, 69 ( 12 ) : 1029 - 1036.
  • 7Holscher T, Ozgur B, Singel S, et al. lntraoperative ultrasound using phase inversion harmonic imaging: first experiences [ J ]. Neurosurgery, 2007, 60 (4 Suppl 2) : 382 -387.
  • 8Kanno H, Ozawa Y, Sakata K, et al. lntraoperative power Doppler uhrasonography with a contrast-enhancing agent for intracranial tumor [J]. J Neurosurg, 2005, 102(2) : 295 -301.
  • 9French LA, Wild JJ, Neal D, et al. Detection of cerebral tumors by ultrasonic pulses: pilot studies on post mortem material[J]. Cancer, 1950, 3 ( 4 ). 705-708.
  • 10LeRoux PD, Winter TC, Berger MS, et al. A compari- son between preoperative magnetic resonance and intra- operative ultrasound tumor volumes and margins [J]. J clin Ultrasound, 1994, 22 ( 1 ):. 20-36.

共引文献109