摘要
焦化废水中的间甲酚质量浓度可达90 mg/L,为了高效处理工业含酚废水,以间甲酚为目标污染物,采用基于硫酸根自由基的HA/Fe^2+/PMS类Fenton体系,考察了各因素对间甲酚降解效能的影响。采用Box-Behnken响应面法优化了反应条件并拟合出回归模型,在反应溶液初始pH=4时,得出最佳反应条件:Fe^2+浓度0.5 mmol/L,PMS投加量5 mmol/L,HA浓度2.5 mmol/L,在此优化条件下,间甲酚去除率为92.84%。
Since the content of m-cresol in the coking wastewater can reach 90 mg/L,it can be used as the targeted contaminant to investigate the treatment efficiency of industrial wastewater containing phenols.A Fenton-like system of HA/Fe^2+/PMS based on sulfate radical was applied to degrade m-cresol.The effects of various factors on the degradation of m-cresol were investigated.The Box-Behnken response surface method was adopted to optimize reaction conditions and fit the regression model.With the initial solution pH of 4,the removal rate of m-cresol reached 92.84%under the optimal conditions,which were found at Fe^2+concentration of 0.5 mmol/L,PMS dosage of 5 mmol/L,and HA concentration of 2.5 mmol/L.
作者
刘屹
许昶雯
王国英
Liu Yi;Xu Changwen;Wang Guoying(College of Environmental Science and Engineering,Taiyuan University of Technology,Taiyuan 030024,China;College of Civil and Architecture Engineering,Chuzhou University,Chuzhou 239000,China)
出处
《工业水处理》
CAS
CSCD
北大核心
2019年第11期45-48,共4页
Industrial Water Treatment
基金
国家自然科学基金(51408396)
山西省研究生联合培养基地人才培养项目(2018JD18)