期刊文献+

固定污染源废气二氧化硫4种监测方法对比 被引量:7

Comparison of Four Monitoring Methods for Sulfur Dioxide from Stationary Source Emission
在线阅读 下载PDF
导出
摘要 目前,固定污染源废气二氧化硫的监测方法主要有碘量法、定电位电解法、非分散红外法和紫外差分吸收光谱法。本文重点综述了这4种监测方法的原理、现场监测过程和注意事项,并提出了一些现场监测经验做法。同时,对4种监测方法的现场监测数据进行对比分析,探讨了数据变化趋势及方法的适用性,结果发现,定电位电解法和非分散红外法不适合高浓度一氧化碳和高含水率的烟气二氧化硫的测量,而碘量法和紫外差分吸收光谱法能够取得满意结果,这为后续固定污染源废气二氧化硫的监测提供了借鉴。 At present,the monitoring methods of sulfur dioxide from stationary sourceemission mainly include iodimetry,fixed-potential electrolysis,non-dispersive infrared absorption and ultraviolet differential absorption spectrometry.This paper summarized the principle,process and points for attention of four monitoring methods in this paper,and then put forward some experiences.At the same time,This paper also compared the monitoring datas of four monitoring methods and analyzed the trends of datas change and applicability of these methods.It was found that the fixed-potential electrolysis and the non dispersive infrared method were inappropriate to situation of high concentration carbon monoxide and high moisture,while the iodimetry method and the ultraviolet differential absorption spectrum method could gain satisfactory results,which could provided reference of monitoring concentration of sulfur dioxide from stationary source emission.
作者 倪广乐 郑强强 李馥星 NI Guangle;ZHENG Qiangqiang;LI Fuxing(Xuzhou Environmental Monitoring Center,Xuzhou Jiangsu 221002;Kuitun Environmental Monitoring Station,Kuitun Xinjiang 833200)
出处 《河南科技》 2019年第26期147-149,共3页 Henan Science and Technology
关键词 固定污染源废气 二氧化硫 碘量法 定电位电解法 非分散红外法 紫外差分吸收光谱法 stationary source emission sulfurdioxide iodimetry fixed-potential electrolysis non-dispersive infrared absorption ultraviolet differential absorption spectrometry
  • 相关文献

参考文献3

二级参考文献7

共引文献45

同被引文献56

引证文献7

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部