期刊文献+

配重垫圈断裂失效分析

Fracture Failure Analysis of Counterweight Washer
在线阅读 下载PDF
导出
摘要 通过宏观检验观察、化学成分分析、硬度测试分析、金相分析和断口分析等方法对某型挖掘机配重垫圈的断裂失效原因进行分析。结果表明:该垫圈热处理不当造成组织不合格,硬度超出设计要求上限值,加大材料脆性同时加大氢脆敏感性,镀锌处理时除氢不及时或除氢不彻底导致氢脆开裂。 The failure cause of counterweight washer of a certain excavator is analyzed by macro inspection observation,chemical composition analysis,hardness test analysis,metallographic analysis and fracture analysis etc.methods.The result show that,improper heat treatment of the washer causes unqualified organization,part hardness exceeds the upper limit of design requirements,these increase material brittleness,at the same time,increase hydrogen embrittlement sensitivity,hydrogen induced delayed cracking due to the dehydrogenation is not timely or the dehydrogenation is not complete during galvanizing treatment.
作者 苏雅萍 SU Ya-ping(Guangxi Liugong Machinery Co.,Ltd.,Liuzhou Guangxi 545007,China)
出处 《装备制造技术》 2019年第11期106-109,共4页 Equipment Manufacturing Technology
关键词 挖掘机 配重垫圈 脆性断裂 氢脆 excavator counterweight washer brittle fracture hydrogen brittleness
  • 相关文献

参考文献3

二级参考文献4

  • 1上海交通大学编写组.金属断口分析[M].国防工业出版社,1979:204-205.
  • 2张栋,钟培道,陶春虎,雷祖圣.失效分析[M].国防工业出版社,2005:324-328.
  • 3李维拥.汽车零部件失效分析文集[C].吉林:吉林科学技术出版社,1991..
  • 4钟群鹏 田永江.失效分析基础知识[M].北京:机械工业出版社,1990.201.