期刊文献+

某600MW机组低氮调整与喷氨优化耦合应用 被引量:4

DeNOx Performance Optimization of Combustion Adjustment and AIG Turning on a 600MW Unit
在线阅读 下载PDF
导出
摘要 对1台600 MW四角切圆的双炉膛燃煤锅炉进行了低氮燃烧调整和SCR脱硝喷氨优化试验。结果表明:通过对燃尽风、炉膛氧量及喷氨格栅各支管流量分配进行了优化,降低了省煤器出口NO x浓度,提高了SCR脱硝反应器出口NO x与氨逃逸浓度分布的均匀性,可有效地预防和减轻空气预热器的硫酸氢铵堵塞,为实现脱硝超低排放稳定运行提供了技术支持,对同类型锅炉设备的降氮优化调整和改造具有借鉴意义。 The optimization adjustment tests of combustion and ammonia-injection-grid(AIG)were carried out in a 600 MW tangentially fired double-furnace boiler.The results showed that after the optimization of the over-firing air,the oxygen in the furnace and the flow distribution of each branch of AIG,the NOx emission concentration in flue gas at the economizer outlet was reduced,the distributions of NOx concentration and ammonia slip of SCR outlet were improved,the block due to the formation of ammonium bisulfate(ABS)in the air preheater can be effectively prevented and alleviated.This paper can supply technical supports for the safe,stable and ultra low emission operation of the unit and it also has certain reference significance on the optimal adjustment and transformation of NO x reduction for the same type units.
作者 方朝君 侯永超 陈嵩涛 邹漳和 FANG Zhaojun;HOU Yongchao;CHEN Songtao;ZOU Zhanghe(Xi’an Thermal Power Research Institute Co.,Ltd.,Suzhou Branch,Suzhou 215153,China;Houshi Power Plant Huayang Electric Industry Co.,Ltd.,Zhangzhou 363105,China)
出处 《锅炉技术》 北大核心 2020年第1期6-9,共4页 Boiler Technology
基金 苏州市科技计划项目(SGC201704)。
关键词 超低排放 双炉膛 四角切圆锅炉 燃烧优化 喷氨优化 ultra-low emissions double-furnace tangential coal-fired boiler combustion optimal adjustment AIG turning
  • 相关文献

参考文献6

二级参考文献49

共引文献97

同被引文献69

引证文献4

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部