期刊文献+

基于有源滤波器的电网三相负载不平衡补偿策略 被引量:3

Three-phase Load Unbalance Compensation Strategy Based on Active Power Filter
在线阅读 下载PDF
导出
摘要 配电网三相不平衡问题会影响电能质量、造成电力系统不稳定运行。目前,电力系统常用的接线方式为三相四线制,传统的针对三相三线制的补偿器只能抑制负序电流,而不能消除零序电流。针对该问题,提出了利用有源电力滤波器进行负载补偿。首先建立了有源滤波器的数学模型,然后分析了补偿电流的监测方法,推导了有源电力滤波器的补偿特性,并在Matlab/Simulink中搭建了三相四线制的补偿模型,对正常性不平衡和故障性不平衡进行了仿真,通过试验结果验证了该方案能够有效减小三相负荷不平衡度。 Three-phase unbalance of distribution network will affect power quality and cause unstable operation of power system.At present,three-phase four-wire system is commonly used in power system.The traditional compensator for three-phase three-wire system can only suppress negative sequence current,but cannot eliminate zero sequence current.To solve this problem,a method that use active power filter for load compensation is proposed.Firstly,the mathematical model of active power filter is established,then the monitoring method of compensation current is analyzed,and the compensation characteristics of active power filter are deduced.A three-phase four-wire compensation model is built in Matlab/Simulink.The normal and fault-type unbalances are simulated.The experimental results verify the proposed model.The scheme can effectively reduce the unbalance of three-phase load.
作者 曹洪 夏令 刘盛 蔡祖军 王浩 CAO Hong;XIA Ling;LIU Sheng;CAI Zujun;WANG Hao(Leshan Shawan Branch of Sichuan Power Supply Company of State Grid,Leshan 614900 China)
出处 《电气工程学报》 2019年第4期72-78,共7页 Journal of Electrical Engineering
关键词 三相不平衡 三相四线制 有源电力滤波器 负载补偿 Three-phase unbalance three-phase four-wire system active power filter load compensation
  • 相关文献

参考文献7

二级参考文献77

共引文献326

同被引文献30

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部