摘要
南宁市位于夏热冬暖地区。本文以该市的一个城市综合体项目为例,重点介绍了其中的超高层办公楼的大温差空调系统设计。文章结合了对该项目的空调冷热源设计,空调水系统竖向分区,大温差小流量下风机盘管修正以及新风系统分区设计等的分析,探讨了超高层大温差空调设计需要关注的问题,提供了一些设计思路。
Nanning is located in the hot summer and warm winter zone. Taking a city complex project in this city as an example, this paper mainly introduces the design of the large temperature difference HVAC system for a super high-rise office building of the project. Based on the analysis of the design of the cooling and heating source, vertical partition of the air conditioning water system, the correction of the fan coil unit in the large temperature difference and small flow state, and the partition design of the fresh air system, this paper discusses the problems that need to be paid attention to in the large temperature difference HVAC system for super high-rise buildings, and provides some design ideas.
作者
陈捷
黄箐
CHEN Jie;HUANG Qing(Hualan Design&Consulting Group)
出处
《建筑热能通风空调》
2020年第2期62-65,共4页
Building Energy & Environment
关键词
夏热冬暖
超高层建筑
大温差
冷热源
水系统竖向分区
设备承压
hot summer and warm winter zone
super high-rise building
large temperature difference
cooling and heating source
vertical zoning of water systems
pressure bearing of equipments