摘要
针对火力发电厂常用的大型热电偶测量板卡的冷端补偿方式,基于现有常用冷端补偿方式所具有的局限性,提出一种通过对板卡内不同测点进行差别化冷端补偿的方式,来改进大型热电偶测量板卡每个测量点的冷端补偿精确度。改进方案已应用到工程应用,运行情况良好。
Aiming at the cold junction compensation method of large thermocouple measurement boards commonly used in thermal power plants,based on the limitations of the existing common cold junction compensation methods,this paper proposes a method for differential cold junction compensation by different measurement points in the board Method to improve the cold junction compensation accuracy of each measurement point of a large thermocouple measurement board.The improvement scheme has been applied to engineering applications,and the operation is in good condition.
作者
马伟东
吴胜华
吴科
Ma Weidong;Wu Shenghua;Wu Ke(Guodian Nanjing Automation Co.,Ltd.,Nanjing,210032,China;Nanjing SAC Valmet Automation Co.,Ltd.,Nanjing,210032,China)
出处
《仪器仪表用户》
2020年第6期88-90,共3页
Instrumentation
关键词
大型热电偶测量板卡
冷端补偿
差别化补偿
精度
large thermocouple measurement board
cold junction compensation
differential compensation
accuracy