期刊文献+

植入型监测装置在慢性心力衰竭患者中的应用进展 被引量:3

Progress in the application of implantable monitoring devices in patients with chronic heart failure
原文传递
导出
摘要 心力衰竭(心衰)发病率高,反复住院导致医疗负担加重,有效降低心衰再住院率面临巨大挑战。血流动力学变化出现在心衰症状之前,及早发现心室充盈压变化是心衰管理的关键。近年来具有远程血流动力学监测功能的心血管植入型电子器械应用于临床指导心衰治疗。本文综述了5类监测慢性心衰患者的植入型电子装置研究现状,并简要介绍了这几类电子装置主要应用价值及植入物相关并发症等。
作者 张小雪 张玲 周贤惠 Zhang Xiaoxue;Zhang Ling;Zhou Xianhui
出处 《中华心律失常学杂志》 2020年第3期333-336,共4页 Chinese Journal of Cardiac Arrhythmias
基金 国家自然科学基金(81660071) 国家重点研发计划(2016YFC0900905)。
  • 相关文献

参考文献3

二级参考文献15

  • 1叶任高 主编.内科学:第5版[M].北京:人民卫生出版社,2001.824.
  • 2Dickstein K,Vardas PE, Auricchio A, et al. 2010 Focused update of ESC guidelines on device therapy in heart failure : an update of the 2008 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure and the 2007 ESC guidelines for cardiac and resynehronization therapy developed with the special contribu- tion of the Heart Failure Association and the European HeartRhythm Association [ J ] .Eur Heart J, 2010,31 : 2677-2687.
  • 3Gu6don-Moreau L, Chevalier P, Marqui6 C, et al. Contributions of remote monitoring to the follow-up of implantable cardioverter defib- rillator leads under advisory[ J] .Eur Heart J ,2010,31:2246-2252.
  • 4Varma N, Epstein AE, Irimpen A, et al.Efficacy and safety of auto- matic remote monitoring for implantable eardioverter defibrillator follow-up:the Lumos-T Safely Reduces Routine O/flee Device Fol- low-up (TRUST) trial[ J ].Circulation, 2010,122 : 325-332.
  • 5Movsowitz C, Mittal S.Remote patient management using implant- able devices [ J ].J Interv Card Electrophysiol, 2011 31 : 81-90.
  • 6Theuns DA, Rivero-Ayerza M, Knops P, et al.Analysis of 57,148 transmissions by remote monitoring of implantable eardioverter de- fibrillators [ J ].Pacing Clin Electrophysiol, 2009,32 : 63-65.
  • 7Crossley GH, Boyle A, Vitense H, et al.The CONNECT ( Clinical Evaluation of Remote Notification to Reduce Time to Clinical Deci- sion) trial :the value of wireless remote monitoring with automaticclinician alerts[ J] .J Am Coil Cardio1,2011,57 : 1181-1189.
  • 8Gudon-Moreau L, Lacroix D, Sadoul N,et al.A randomized study of remote follow-up of implantable cardioverter defibrillators:safety and efficacy report of the ECOST trial[J] .Eur Heart J,2013,34:605-614.
  • 9Shanmugam N, Boerdlein A, Proff J, et al. Detection of atrial high- rate events by continuous Home Monitoring:clinical significance in the heart failure-cardiac resynchronization therapy population[ J]. Europace, 2012,14 : 230-237.
  • 10Landolina M, Perego GB, Lunati M, et al.Remote monitoring reduces healthcare use and improves quality of care in heart failure patients with implantable defibrillators:the evolution of management strate- gies of heart failure patients with implantable defibrillators ( EVOL- VO) study [ J ].Circulation, 2012,125 : 2985-2992.