摘要 列车正常运行过程中,不可避免会出现受电弓与接触网脱离接触的情况,就会造成供电电压中断,影响列车安全稳定运行。针对这一实际工程问题,提出一种依据采样计算网压基波电压的幅值、锁相环(PLL)相位差值及电流计算的综合检测及控制方法。该方法已经在1.8 MW高功率因数整流器上得到实现,并通过半实物仿真测试和地面联调试验验证了该方法的正确性与可行性.降低了因铁路恶劣供电条件造成的安全隐患。 During the normal operation of the train,it is inevitable that the pantograph will come out of contact with the catenary,which will cause the interruption of power supply voltage and affect the safe and stable operation of the train.Aiming at this practical engineering problem,a comprehensive detection and control method based on sampling to calculate the amplitude of voltage base wave,phase-locked loop(PLL)phase difference and current calculation is proposed.The method has been implemented on 1.8 MW high power factor rectifier,and the correctness and feasibility of the method have been verified by semi-physical simulation test and ground joint adjustment test,and the hidden danger caused by bad railway power supply conditions has been reduced.
作者 王力 于森林 张瑞峰 詹哲军 WANG Li;YU Sen-lin;ZHANG Rui-feng;ZHAN Zhe-jun(Technical Center,CRRC Yongji Motor Co.,Ltd.,Xi'an 710016,China)
出处 《电力电子技术》 CSCD 北大核心 2020年第7期50-53,共4页 Power Electronics
基金 中国中车重大项目(2020CTA098)。
关键词 变流器 网压中断 半实物仿真 地面联调试验 converter grid voltage interruption semi-physical simulation ground joint adjustment test
  • 相关文献

参考文献2

二级参考文献20

  • 1王义锋,金新民.关于单相PWM整流器二次吸收回路的研究[J].电力电子,2003,1(5):39-41. 被引量:3
  • 2李学亮,宋建成,郑丽君.基于纹波电压补偿的单相PWM可逆整流器的研究[J].电气技术,2008,9(5):65-68. 被引量:8
  • 3李春龙,沈颂华,卢家林,张建荣,白小青,石涛.基于状态观测器的PWM整流器电流环无差拍控制技术[J].电工技术学报,2006,21(12):84-89. 被引量:30
  • 4王剑.四象限级联型多电平变换器用PWM整流器高性能控制[D],清华大学电机系,2009.
  • 5Ho C N, Cheung V S, Chung H S. Constant-frequency hysteresis current control of grid-connected VSI without bandwidth control[J]. IEEE Transactions on Power Electronics, 2009, 24(11): 2484-2495.
  • 6Blasko V, Kaura V. A new mathematical model and control of a three-phase AC-DC voltage source converter[J]. IEEE Transactions on Power Electronics, 1997, 12(1): 116-123.
  • 7Zmood D N, Holmes D G, Bode G H. Frequency-domain analysis of three-phase linear current regulators[J]. IEEE Transactions on Industry Applications, 2001, 37(2): 601-610.
  • 8Zmood D N, Holmes D G. Stationary frame current regulation of PWM inverters with zero steady-state error[J]. IEEE Transactions on Power Electronics, 2003, 18(3): 814-822.
  • 9Yuan X, Merk W, Stemmler generalized integrators for H, et al. Stationary-frame current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions[J]. IEEE Transactions on Industry Applications, 2002, 38(2): 523-532.
  • 10Holmes D G, Lipo T A, McGrath B P, et al. Optimized design of stationary frame three phase AC current regulators[J]. IEEE Transactions on Power Electronics, 2009, 24(11): 2417-2426.

共引文献41

同被引文献11

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部